Acta Chir Orthop Traumatol Cech. 1993; 60(5):273-277

Wave plate osteosynthesis as a salvage procedure.

G Blatter, B G Weber
Departement of Orthopedic Surgery Kantonsspital, St. Gallen, Switzerland.

The load axis of the curved-shaped proximal femur lies not inside, but outside the bone. Therefore high bending forces are acting, the medial cortex absorbing pressure, the lateral cortex absorbing tension. In a transverse fracture, a laterally applied plate will absorb the tensile stresses, the medial cortex the pressure forces. When medial butress due to bony defect is missing, the laterally applied plate is subjected to cycling bending and will undergo fatigue fracture. This dilemma is compensated by a wave-plate with bone graft: The compression forces are detoured to the lateral cortex and the plate is again subjected to tension. Furthermore since the plate is standing away from the bone, the plate does not disturb the blood supply at the fracture side and bone healing.

Published: January 1, 1993  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Blatter G, Weber BG. Wave plate osteosynthesis as a salvage procedure. Acta Chir Orthop Traumatol Cech. 1993;60(5):273-277. PubMed PMID: 8285004.