Acta Chir Orthop Traumatol Cech. 1995; 62(2):114-116

[Dislocation of an endoprosthesis of the hip joint operated by the open method.].

J Musialek, K Foldyna, J Kundrát
Ortopedické oddelení Mestské nemocnice, Ostrava Fifejdy.

The authors evaluated in a series of endoprostheses of the hip joint the X-ray documentation and peroperative revision findings in 8 patients who from a total of 16 dislocations (2.2%) were subjected to surgical revision. Conditions of a postdysplastic hip joint with previous surgery predominated (62%). In half the reoperated hip joints the cause of dislocation was a malposition of one of the components. The most frequent surgical revision was replacement by a femoral component with a longer neck (88%). Key words: endoprosthesis of the hip joint, dislocation, treatment of dislocation.

Zveřejněno: 1. leden 1995  Zobrazit citaci

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Musialek J, Foldyna K, Kundrát J. [Dislocation of an endoprosthesis of the hip joint operated by the open method.]. Acta Chir Orthop Traumatol Cech. 1995;62(2):114-116. PubMed PMID: 20470495.
Stáhnout citaci