Acta Chir Orthop Traumatol Cech. 2007; 74(4):278-286 | DOI: 10.55095/achot2007/044

Výsledky implantace silastikových náhrad MCP kloubů II-V u revmatikůPůvodní práce

J. DOBIÁŠ*, J. PECH, S. POPELKA
I. ortopedická klinika 1. LF UK a FN Motol, Praha

PURPOSE OF THE STUDY:
The authors evaluate the long-term results of metacarpophalangeal joint (MCP) arthroplasty of the second to fifth digits in the rheumatoid hand in relation to the factors that have a long-term effect on implant function.

MATERIAL:
In a group of 41 patients, 52 hands were treated with a total of 166 Swanson silastic MCP implants in the period from 1988 to 2005. The average follow-up was 3.2 years (range, 6 months to 17 years). Arthroplasty was carried out exclusively for the indication of rheumatoid destruction of MCP joints.

METHODS:
The patients were assessed for the range of motion, MCP joint alignment and functional and radiographic findings. X-ray images were examined for osseous lesions at the margins of resected parts, implant position and its state and joint alignment. Radiography was performed from the standard distance in anteroposterior and oblique projections. Subjective satisfaction of the patients was evaluated on the basis of a questionnaire, in which hand function, pain and cosmetic appearance were recorded.

RESULTS:
The function and mobility of the fingers improved after surgery, with an increased range of motion in MCP joints towards extension (average range, 3° to 51° flexion), and correction of an ulnar drift of the MCP joint of each finger (average, 5.8°). Radiographs showed destruction of silastic implants in 13.3 % of the fingers treated. The subjective evaluation by patients was satisfactory. Long-lasting pain relief was reported by 79 % and satisfaction with hand function by 90 % of the patients. Improvement in a cosmetic appearance of the hand was also significant.

DISCUSSION:
At long-term follow-up, a gradual decrease in the range of motion of MCP joints and a partial recurrence of ulnar drift usually occur at about 2 years. However, in most cases, they do not result in either subjective complaints or functional restriction. These findings are in agreement with the results published in the relevant literature.

CONCLUSIONS:
The silastic implant remains a standard procedure in surgical reconstruction of the MCP joints in the rheumatoid hand. Improvements in the range of motion and joint alignment and alleviation of pain result in a markedly improved hand function and patients' satisfaction. The long-term outcome of MCP joint arthroplasty is significantly influenced by the severity of rheumatoid arthritis.

Klíčová slova: MCP joint replacement, rheumatoid hand, silastic implant

Přijato: 29. leden 2007; Zveřejněno: 1. srpen 2007  Zobrazit citaci

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
DOBIÁŠ J, PECH J, POPELKA S. Výsledky implantace silastikových náhrad MCP kloubů II-V u revmatiků. Acta Chir Orthop Traumatol Cech. 2007;74(4):278-286. doi: 10.55095/achot2007/044. PubMed PMID: 17877946.
Stáhnout citaci

Reference

  1. BAŘINKA, L.: Polyetylenová endoprotéza malých kloubů ruky. Služba zdravotníkům, 1: 30-31, 1981.
  2. BIEBER, E. J., WEILAND, A. J., VOLENEC-DOWLING, S.: Silicone-rubber implant arthroplasty of the metacarpophalangeal joints for rheumatoid arthritis. J. Bone Jt Surg., 68-A: 206-209, 1986. Přejít k původnímu zdroji...
  3. EL-GAMMAL, T. A., BLAIR, W. F.: Motion after metacarpophalangeal joint reconstruction in rheumatoid disease. J. Hand Surg., 18-A: 504-511, 1993. Přejít k původnímu zdroji... Přejít na PubMed...
  4. FLATT, A. E.: The care of the rheumatoid hand. St. Louis, CV Mosby 1983, 277.
  5. FOWLER, S. B.: Arthroplasty of the metacarpophalangeal joints in rheumatoid arthritis. J. Bone Jt Surg., 44-A: 1037, 1962.
  6. GOLDRARB, C. A., STERN, P. J.: Metacarpophalangeal joint arthroplasty in rheumatoid arthritis. A long-term assessment. J. Bone Jt Surg., 85-A: 1869-1878, 2003. Přejít k původnímu zdroji... Přejít na PubMed...
  7. GSCHWEND, N.: Die operative Behandlung der polyarthritis. Stuttgart, Thieme 1977, 319.
  8. CHUNG, K. C., KOTSIS, S. V., KIM, H. M.: A prospective outcomes study of Swanson metacarpophalangeal joint arthroplasty for the rheumatoid hand. J. Hand Surg., 29-A: 646-653, 2000. Přejít k původnímu zdroji... Přejít na PubMed...
  9. JAKUBÍK, J.: Silikonové implantáty československé výroby v rekonstrukční chirurgii ruky. Kandidátská dizertační práce, Brno, 1981.
  10. KIRCHENBAUM, D., SCHNEIDER, L. H., ADAMS, D. C., CODY, R. P.: Arthroplasty of the metacarpophalangeal joints with use of silicone-rubber implants in patients who have rheumatoid arthritis. Long-term results. J. Bone Jt Surg., 75-A: 3-12, 1993. Přejít k původnímu zdroji... Přejít na PubMed...
  11. MAURER, R. J., RANAWAT, C. S., McCORMACK, R. R., INGLIS, A. E., STRAUB, L. R.: Long-term follow-up of the Swanson MP arthroplasty for rheumatoid arthritis. J. Hand Surg., 15-A: 810-811, 1990.
  12. MILLENDER, L. H., NALLEBUFF, E. A.: Reconstructive surgery in the rheumatoid hand. Orthop. Clin. N. Amer., 6: 709-732, 1975. Přejít k původnímu zdroji...
  13. NIEBAUER, J. J.: Dacron-silicone prosthesis for the metacarpophalangeal and interphalangeal joints. In: Cramer, R. M., Chase, R. A.: Symposium on the hand. Vol. 3, St. Louis, CV Mosby 1971, 96-105. Přejít k původnímu zdroji...
  14. PECH, J., POPELKA, S., DOSKOČIL, M., PAVELKA, K.: Revmatochirurgie ruky. Praha, Schola nova Comenium 2000.
  15. POPELKA, S., RYBKA, V.: Revmatochirurgie. Praha, Avicenum 1989.
  16. RYBKA, V., PECH, J., POPELKA, S.: Zásady aplikace silikonových implantátů kloubů ruky podle Swansona. Acta Chir. orthop. Traum. čech., 52: 212-220, 1985.
  17. SCHMIDT, K., WILLBURGER, R. E., MIEHLKE, R. K., WITT, K.: Ten-year follow-up of arthroplasty of the metacarpophalangeal joints in rheumatoid hands. Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery, 33: 433-438, 1999. Přejít k původnímu zdroji... Přejít na PubMed...
  18. STRAUB, L. R.: Intrinsic muscle in disease with particular reference to the rheumatoid hand. Paris, Dexieme Congress Internationale de Chirurgie Orthopedique et Traumatologie, 1969, 863-872.
  19. SWANSON, A. B.: Silicone rubber implants for replacement of arthritic or destroyed joints in the hand. Surg. Clin. N. Amer., 48: 1113-1127, 1968. Přejít k původnímu zdroji... Přejít na PubMed...
  20. SWANSON, A. B., SWANSON, G. DEG., ISHIKAWA, H.: Use of grommets for flexible implant resection arthroplasty of the metacarpophalangeal joint. Clin. Orthop., 342: 22-33, 1997. Přejít k původnímu zdroji...
  21. WILSON, Y. G., SYKES, P. J., NIRANJAN, N. S.: Long-term follow-up of Swanson's silastic arthroplasty of the metacarpophalangeal joints in rheumatoid arthritis. J. Hand Surg., 18-B: 81-91, 1993. Přejít k původnímu zdroji... Přejít na PubMed...