Acta Chir Orthop Traumatol Cech. 2010; 77(6):479-483 | DOI: 10.55095/achot2010/079

Výsledky léčby zlomenin distálního humeru otevřenou repozicí a vnitřní fixací LCP-DHPPůvodní práce

CH. GEORGIADES, J. MATĚJKA*, T. PAVELKA, P. HOUČEK
Klinika ortopedie a traumatologie pohybového ústrojí FN a LF UK v Plzni

PURPOSE OF THE STUDY:
The aim of this retrospective study was to evaluate the group of 27 patients with distal humeral fractures treated by the locking compression plate and distal humerus plate (LCP-DHP) system.

MATERIAL:
Between January 2006 and June 2008, a total of 62 distal humeral fractures (61 patients) were treated in our department, of which 27 were managed by LCP-DHP. The group comprised 15 women (55.5 %) and 12 men (45.5 %), with an average age of 53.6 years (range, 18 to 84 years).

METHODS:
Conservative reduction and subsequent immobilization were done in all fractures. The surgical procedure was indicated within 24 hours of injury, with neurological deficit or an open fracture this was 6 hours. Access to the fracture was from a longitudinal dorsal incision with intra-articular osteotomy of the olecranon. The ulnar nerve was released and transposed. The fractures were reduced with an effort of maximal restoration of the articular surface, and then fixed with LCP-distal humerus plates. Antibiotic prophylaxis was administered and the wound was drained and a drain was inserted. The arm was immobilized in a plaster cast or a removable brace for 2 to 4 weeks, according to the fracture type. The patients had clinical and X-ray follow-up at 6 weeks, then at 3, 6 and 12 months after surgery. The evaluation was based on the Mayo elbow performance score (MEPS).

RESULTS:
The injury was caused by a fall in 24 patients (88.9 %), sustained in a car accident in two (7.4 %) and as the result of a gunshot in one patient (3.7 %).
Multiple injuries to the musculoskeletal system were diagnosed in five patients (18.5 %). One patient with polytrauma after a fall from 6 metres suffered an ipsilater fracture of the distal femur (3.7 %). The two patients involved in car accidents (7.4 %) had injury to the contralateral acetabulum. Two patients (7.4 %) sustained distal radial fractures on the other side. Surgery was carried out within 10.5 hours (4 to 47) of injury on the average. The average hospital stay was 6.4 days (2 to 12). All 27 fractures were classified as AO type C fractures, of these seven were open fractures.
Complete bony union was achieved at an average of 4 months, with a range of 3 to 9 months (in two patients 7.4 %) after surgery. The early post-operative complications included wound dehiscence due to superficial infection in two patients. In two patients early removal of the implants was indicated, and this was for ulnar nerve irritation and motion range restriction in one and deep infection in the other. No migration or failure of the implants was recorded.
The average MEPS of the patient group was 91.6, which is in the range of excellent to very good results.

DISCUSSION:
The group of our patients is by age, sex and AO type C fractures comparable with the groups of other authors. The number of complications is lower and the MEPS evaluation is comparable. Even when full anatomic reduction and stable fixation are achieved, the outcome may be compromised by heterotrophic ossification, joint rigidity or ulnar neuropathy, the facts described by the majority of authors. Similarly, it is reported that good results are obtained with intra-articular osteotomy of the olecranon and ulnar nerve transposition.
An important component of the treatment is good quality physical therapy restoring a satisfactory range of motion.

CONCLUSIONS:
The study provided evidence that the use of LCP-DHP provides stable fixation of type C fractures, even in patients with osteoporosis, and when completed with early rehabilitation, it has good clinical outcomes.

Klíčová slova: distal humerus fracture, olecranon osteotomy, locking compression plate, LCP-DHP

Zveřejněno: 1. prosinec 2010  Zobrazit citaci

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
GEORGIADES C, MATĚJKA J, PAVELKA T, HOUČEK P. Výsledky léčby zlomenin distálního humeru otevřenou repozicí a vnitřní fixací LCP-DHP. Acta Chir Orthop Traumatol Cech. 2010;77(6):479-483. doi: 10.55095/achot2010/079. PubMed PMID: 21223827.
Stáhnout citaci

Reference

  1. BARTONÍČEK, J.: Zlomeniny distálního konce humeru. Acta Chir. orthop. Traum. čech., 62: 20-35, 1995.
  2. BARTONÍČEK, J., HEŘT, J.: Základy klinické anatomie pohybového aparátu. Praha, Maxdorf 2004.
  3. CASSENBAUM, W. H.: Open reduction of T and Y fractures of the lower end of the humerus. J. Trauma, 9: 915-925, 1969. Přejít k původnímu zdroji... Přejít na PubMed...
  4. ČECH, O., STRYHAL, F., BEZNOSKA, S., SOSNA, A.: Stabilní osteosyntéza v traumatologii a ortopedii. Praha, Avicenum 1982.
  5. GREINER, S., HAAS, N. P., BAIL, H. J.: Outcome after open reduction and angular stable internal fixation for supra-intercondylar fractures of the distal humerus: preliminary results with the LCP distal humerus system. Arch. Orthop. Trauma Surg., 128: 723-729, 2008. Přejít k původnímu zdroji... Přejít na PubMed...
  6. ILYAS, A. M., JUPITER, J. B.: Treatment of distal humerus fractures. Acta Chir. orthop. Traum. čech., 75: 6-15, 2008. Přejít k původnímu zdroji...
  7. JOHN, H. M., ROSO, R., NEFF, U., BODOKY, A., REGAZZONI, P., HARDER, F.: Operative treatment of distal humerus fractures in the elderly. J. Bone Jt Surg., 76-B: 793-796, 1994. Přejít k původnímu zdroji...
  8. JUPITER, J. B., MEHNE, D. K.: Fractures of the distal humerus. Orthopaedics, 15: 25-833, 1992. Přejít k původnímu zdroji... Přejít na PubMed...
  9. JUPITER, J. B., NEFF, U., HOLZACH, P., ALLGÖWER, M.: Intraarticular distal humerus fractures. J. Bone Jt Surg., 67-A: 226-239, 1985. Přejít k původnímu zdroji...
  10. KINIK, H., ATALAR, H., MERGEN, E.: Management of distal humerus fractures in adults. Arch. Orthop. Trauma Surg., 119: 467-469, 1999. Přejít k původnímu zdroji... Přejít na PubMed...
  11. KONRAD, G. G., MELHRON, A., KÜHLE, J., STROHM, P. C., SÜDKAMP, N. P.: Proximal humeral fractures - Current treatment options. Acta Chir. orthop. Traum. čech., 75: 413-421, 2008. Přejít k původnímu zdroji...
  12. KORNER, J., LILL, H., MÜLLER, L. P., ROMMENS, P. M., SCHNEIDER, E., LINKE, B.: The LCP concept in the operative treatment of distal humerus fractures-biological, biomechanical and surgical aspects. Injury, 34: 20-30, 2003. Přejít k původnímu zdroji... Přejít na PubMed...
  13. KRBEC, M., MOTYČKA, J., LUŇÁČEK, L., DOUŠA, P.: Osteosyntéza periprotetické suprakondylické zlomeniny kolenního kloubu s použitím LCP dlahy. Acta Chir. orthop. Traum. čech., 76: 473-478, 2009. Přejít k původnímu zdroji...
  14. KŘIVOHLÁVEK, M., LUKÁŠ, R., TALLER, S., ŠRÁM, J.: Acta Chir. orthop. Traum. čech., 75: 212-220, 2008. Přejít k původnímu zdroji...
  15. KUNDEL, K., BRAUN, W., HOLZACH, WIEBRENEIT, J., RÜTTER, A.: Intraarticular distal humerus fractures. Clin. Orthop., 332: 200-208, 1996. Přejít k původnímu zdroji...
  16. KYU, H. Y., HUI W. P., SUN JIN, P., SUNG, H. J.: Lateral J. plate fixation in comminuted intercondylar fractures of the distal humerus. Arch. Orthop. Trauma Surg., 123: 234-238, 2003. Přejít k původnímu zdroji... Přejít na PubMed...
  17. MORREY, B. F., ADAMS, R. A.: Semiconstrained arthroplasty for the treatment of rheumatoid arthritis of the elbow. J. Bone Jt Surg, 74-A: 479-490, 1992. Přejít k původnímu zdroji...
  18. NIEMEYER, P., SÜDKAMP, N. P.: Principles and clinical application of the Locking compression plate (LCP). Acta Chir. orthop. Traum. čech., 73: 221-228, 2006. Přejít k původnímu zdroji...
  19. O'DRISCOLL, S. W.: Optimizing stability in distal humeral fracture fixation. J. Shoulder Elbow Surg., 14: 186-194, 2005. Přejít k původnímu zdroji... Přejít na PubMed...
  20. PERREN, S. M.: Fracture Healing. The evolution of our understanding. Acta Chir. orthop. Traum. čech., 75: 241-246, 2008. Přejít k původnímu zdroji...
  21. RÜBBERDT, A., SURKE, C., FUCHS, T., FRERICHMANN, U., MATUSZEWSKI, L., VIETH, V., RASCHKE, M. J.: Preformed plate-fixation system for type AO 13C3 distal humerus fractures: clinical experiences and treatment results taking access into account. Unfallchirurg, 111: 308-322, 2008. Přejít k původnímu zdroji... Přejít na PubMed...
  22. SCHMIDT-HORLOHÉ, K., BONK, A., WILDE, P., BECKER, L., HOFFMANN, R.: Functional results after osteosynthesis of the distal humerus fracture with an anatomically precontoured, angular-stable double plate system. Z. Orthop. Unfall. 148: 300-308, 2010.
  23. SCHUSTER, I., KORNER, J., ARZDORF, M., SCHWIEGER, K., DIEDERICHS, G., LINKE, B.: Mechanical comparison in cadaver specimen of 3 different 90-degree double plate osteosynthesis for simulated C2 type distal humerus fractures with varying bone densities. J. Orthop. Trauma, 22: 113-120, 2008. Přejít k původnímu zdroji... Přejít na PubMed...
  24. SOEDERGARD, J., SANDELIN, J., BOESTMAN, O.: Postoperative complications of distal humeral fractures. Acta orthop. scand., 63: 85-89, 1992. Přejít k původnímu zdroji... Přejít na PubMed...
  25. SOSNA, A., ČECH, O., KRBEC, M.: Operační přístupy ke skeletu končetin, pánve a páteře. Praha, Triton 2005.
  26. STOFFEL, K., CUNEEN, S., MORGEN, R., NOCHOLLS, R., STACHOWIAK, G.: Comparative stability of perpendicular versus paralel double locking plating systeme in osteoporotic comminuted distal humerus fractures. J. Orthop., 26: 778-784, 2008. Přejít k původnímu zdroji... Přejít na PubMed...
  27. STROHM, P. C., HELWIG, P., KONRAD, G., SÜDKAMP, N. P.: Locking plates in proximal humerus fractures. Acta Chir. orthop. Traum. čech., 74: 410-415, 2008. Přejít k původnímu zdroji...
  28. ZEMAN, P., ZEMAN, J., MATĚJKA, J., KOUDELA, K.: Střednědobé zkušenosti s léčbou zlomenin patní kosti otevřenou repozicí a vnitřní fixací kalkaneární LCP z rozšířeného laterálního přístupu. Acta Chir. orthop. Traum. čech., 75: 457-464, 2008. Přejít k původnímu zdroji...