PURPOSE OF THE STUDY:
Avulsion fractures of the intercondylar eminence (ICE) of the tibia have become increasingly frequent in older school age. Due to recent advances in arthroscopic techniques, it is now possible to treat them by minimally invasive methods. This retrospective study presents evaluation of clinical outcomes of an arthroscopic technique using crossed K-wires.
MATERIAL:
Thirty-five patients with ICE avulsion fracture, 17 girls and 18 boys at an average age of 13 years (7-18), were included in this study. All were indicated for surgical treatment on the basis of radiographic evidence of McKeever type II and III fractures.
METHODS:
The technique of arthroscopic reduction and fixation with crossed K-wires was used. The clinical evaluation of knee stability (anterior drawer test and Lachmann s-test) was made by one clinician. The modified Tegner-Lysholm score was assessed.
RESULTS:
Of the 35 patients, 26 (74%) had minimal knee instability (anterior drawer up to 5 mm), two patients were primarily converted to open reduction with good results, and three (8.5%) experienced temporary knee instability (anterior drawer of 5-10 mm) that resolved spontaneously within 24 months of surgery. Four patients (11.5%) had symptoms of persistent residual instability (anterior drawer more than 10 mm) and were indicated for anterior cruciate ligament reconstruction at a later stage. The average Tegner-Lysholm scores were 86.3/100 and 98.6/100 at 6 and 24 months, respectively.
DISCUSSION:
At the present time at our department, McKeever type II and III avulsion fractures of the intercondylar eminence are indicated for minimally invasive surgical treatment. By exact reduction it is possible to decrease the risk of post-operative knee instability. The current trend is the use of arthroscopy-assisted minimally invasive techniques such as the method of K-wire fixation described here.
CONCLUSIONS:
Arthroscopic surgery for ICE avulsion fractures shows good results, is associated with low post-operative risks, is minimally invasive and easy to reproduce. It can be recommended as the method of choice for treating ICE avulsion injury in children.
Klíčová slova: intercondylar eminence, knee arthroscopy, minimally invasive surgery, ACL, paediatric trauma
Zveřejněno: 1. srpen 2011 Zobrazit citaci
ACS | AIP | APA | ASA | Harvard | Chicago | Chicago Notes | IEEE | ISO690 | MLA | NLM | Turabian | Vancouver |
Reference
- AHN, J.H., YOO, J. C.: Clinical outcome of arthroscopic reduction and suture for displaced acute and chronic tibial spine fractures. Knee Surg. Sports Traumatol. Arthrosc., 3(2): 116-21, 2005.
Přejít k původnímu zdroji...
Přejít na PubMed...
- FURLAN, D., POGORELIC, C., BIOCIC, M., JURIC, I., MESTROVIC, C.: Pediatric tibial eminence fractures: arthroscopic treatment using K-wire. Scand. J. Surg., 99(1): 38-44, 2010.
Přejít k původnímu zdroji...
Přejít na PubMed...
- GUI, J., WANG, L., JIANG, Y., WANG, Q., YU, Z., GU, Q.: Single-tunnel suture fixation of posterior cruciate ligament avulsion fracture. Arthroscopy, 25(1): 78-85, 2009.
Přejít k původnímu zdroji...
Přejít na PubMed...
- HUANG, T. W., HSU, K. Y., CHENG, C. Y., CHEN, L. H., WANG, C. J., CHAN, Y. S., CHEN, W. J.: Arthroscopic suture fixation of tibial eminence avulsion fractures. Arthroscopy, 24(11): 1232-8, 2008.
Přejít k původnímu zdroji...
Přejít na PubMed...
- HUNTER, R. E., WILLIS, J. A.: Arthroscopic fixation of avulsion fractures of the tibial eminence: technique and outcome. Arthroscopy, 20(2): 113-21, 2004.
Přejít k původnímu zdroji...
Přejít na PubMed...
- KOCHER, M. S., MICHELI, L. J., GERBINO, P., HRESKO, M. T.: Tibial eminence fractures in children: prevalence of meniscal entrapment. Am. J. Sports Med., 31(3): 404-7, 2003.
Přejít k původnímu zdroji...
Přejít na PubMed...
- LOWE, J., CHAIMSKY, G., FREEDMAN, A., ZION, I., HOWARD, C.: The anatomy of tibial eminence fractures: arthroscopic observations following failed closed reduction. J. Bone Jt Surg. Am., 84-A(11): 1933-8, 2002.
Přejít k původnímu zdroji...
- LUBOJACKÝ, J.: Tibial Tubercle Avulsion Fracture - an Original Method of Fragment Fixation by K-Wires. Acta Chir. orthop. Traum. čech., 73: 403-404, 2006.
Přejít k původnímu zdroji...
- LUKÁŠ, L., KOUDELA, K.: Fractures of the intercondylar eminence of the tibia. Acta Chir. orthop. Traum. čech., 71(3): 171-5, 2004.
- MATTHEWS, D. E., GEISSLER, W.B.: Arthroscopic suture fixation of displaced tibial eminence fractures. Arthroscopy, 10(4): 418-23, 1994.
Přejít k původnímu zdroji...
Přejít na PubMed...
- MEYERS, M. H., McKEEVER, F. M.: Fracture of the intercondylar eminence of the tibia. J. Bone Jt Surg. Am., 52(8): 1677-84, 1970.
Přejít k původnímu zdroji...
- PARK, H. J., URABE, K., NARUSE, K., AIKAWA, J., FUJITA, M., ITOMAN, M.: Arthroscopic evaluation after surgical repair of intercondylar eminence fractures. Arch. Orthop. Trauma Surg., 127(9): 753-7, 2007.
Přejít k původnímu zdroji...
Přejít na PubMed...
- PAŠA, L., VIŠŇA, P., KOČIŠ, J., MUŽÍK, V., VESELÝ, R.: Arthroscopic stabilization of the fractured intercondylar eminence. Acta Chir. Orthop. Traum. čech., 72(3): 160-3, 2005.
- REYNDERS, P., REYNDERS, K., BROOS, P.: Pediatric and adolescent tibial eminence fractures: arthroscopic cannulated screw fixation. J. Trauma., 53(1): 49-54, 2002.
Přejít k původnímu zdroji...
Přejít na PubMed...
- SENEKOVIC, V., VESELKO, M.: Anterograde arthroscopic fixation of avulsion fractures of the tibial eminence with a cannulated screw: five-year results. Arthroscopy, 19(1): 54-61, 2003.
Přejít k původnímu zdroji...
Přejít na PubMed...
- TEGNER, Y., LYSHOLM, J.: Rating systems in the evaluation of knee ligament injuries. Clin. Orthop. Relat. Res. Sep;(198): 43-9, 1985.
Přejít k původnímu zdroji...
- VALIŠ, P., REPKO, M., NÝDRLE, M., CHALOUPKA, R.: Surgical Management of Posterior Cruciate Ligament Avulsion Fracture. Acta Chir. orthop. Traum. čech., 75(1): 34-39, 2008.
Přejít k původnímu zdroji...
- VanDERHAVE, K. L., GANLEY, T. J., KOCHER, M. S., PRICE, C. T., HERRERA-SOTO, J. A.: Arthrofibrosis after surgical fixation of tibial eminence fractures in children and adolescents. Am. J. Sports Med., 38(2): 298-301, 2010.
Přejít k původnímu zdroji...
Přejít na PubMed...
- VEGA, J. R., IRRIBARRA, L. A., BAAR, A. K., INIGUEZ, M., SALGADO, M., GANA, N.: Arthroscopic fixation of displaced tibial eminence fractures: a new growth plate-sparing method. Arthroscopy, 24(11): 1239-43, 2008.
Přejít k původnímu zdroji...
Přejít na PubMed...
- ZHAO, J., HUANGFU, X.: Arthroscopic treatment of nonunited anterior cruciate ligament tibial avulsion fracture with figure-of-8 suture fixation technique. Arthroscopy, 23(4): 405-10, 2007.
Přejít k původnímu zdroji...
Přejít na PubMed...
- ZWINGMANN, J., SCHMAL, H., MEHLHORN, A., SUDKAMP, N. P., STROHM, P. C.: Injury Patterns in Polytraumatized Children and Consequences for the Emergency Room Management. Acta Chir. orthop. Traum. čech., 77(5): 365-370, 2010.
Přejít k původnímu zdroji...