Acta Chir Orthop Traumatol Cech. 2012; 79(4):361-366 | DOI: 10.55095/achot2012/052

Porovnání efektivnosti pooperačního retransfuzního systému s perioperačním autotransfuzním systémem při implantacích totálních endoprotéz kolenního kloubuPůvodní práce

B. KUČERA1,*, D. NÁHLÍK1, R. HART1,2, L. OCELÁKOVÁ1
1 Ortopedicko-traumatologické oddělení Nemocnice Znojmo
2 Klinika traumatologie v Úrazové nemocnici v Brně, LF MU, Brno

PURPOSE OF THE STUDY:
The aim of the study was to compare the effect of post-operative retransfusion with that of intra-operative autotransfusion in non-anaemic patients undergoing total knee arthroplasty (TKA).

MATERIAL AND METHODS:
Between February 2004 and June 2006, a total of 129 patients free of anaemia who underwent elective primary unilateral cemented TKA for primary arthritis received blood retransfusion by means of the post-operative retransfusion system. Intra-operative transfusion was not administered. Patients with coagulation disorders, thrombocytopaenia or other haematological diseases were not included. The results were compared with those of the group of 142 patients undergoing the same surgery, but with use of the intra-operative autotransfusion system, in the period from February 2009 to December 2010.
The following patient data were reviewed: patient's age at the time of surgery; value of haemoglobin before and two days after surgery; allergic and febrile reactions associated with retransfusion, renal failure after retransfusion, number of post-operative allogeneic transfusions, early TKA infection and thrombo-embolic complications.

RESULTS:
Of the 129 patients with post-operative retransfusion, 25 received one or more allogeneic blood transfusions due to the haemoglobin level below 90g/l and symptoms of anaemia. The average haemoglobin level was 136 g/l (range, 111 to 159 g/l) one day before surgery and 107 g/l (range, 81 to 143 g/l) on the 2nd post-operative day. A single allogeneic blood transfusion was administered to 12 patients and two were necessary in 13 patients. The average blood volume returned to the patient through the post-operative retransfusion system was 725.3 ml (range, 250 to 1 300 ml).
Of the 142 patients with intra-operative autotransfusion, 11 patients required blood transfusion in the post-operative period, with seven receiving one and four receiving two transfusions. The average haemoglobin level was 135 g/l (range, 110 to 161 g/l) one day before surgery and 107 g/l (range, 85 to 130 g/l) two days after it. The average volume of erythrocyte mass returned to the patient through the intra-operative autotransfusion system was 330.7 ml (range, 0 to 850 ml). No allergic, pyretic or other reaction or complication was recorded in either group. No early TKA infection occurred.

DISCUSSION:
No reports comparing the efficacies of post-operative retransfusion and intra-operative auto-transfusion systems in patients undergoing total knee replacement have been found in the literature. Therefore, the only possible comparison can be made with the studies that involve patients receiving blood recuperation and control groups with no blood recuperation. In our study, 19.3% of the patients with post-operative retransfusion required allogeneic blood transfusion while this was necessary in only 7.7% of the patients with intra-operative autotransfusion. This difference was caused by a better efficiency of the intra-operative autotransfusion system which can treat up to 2 litres of harvested blood per hour and return it to the patient in the form of erythrocyte mass, while the post-operative retransfusion system can salvage only 1500 ml of blood.

CONCLUSIONS:
The use of either of these systems has proved to be a simple and safe method of reducing the need of allogeneic blood transfusion in the TKA procedure. While the post-operative retransfusion system facilitates the return of drained blood only, the more efficient "cell-saver" technology collects blood shed during both intra- and post-operative periods and allows for erythrocyte mass retransfusion during and after surgery. Since the administration of allogeneic blood was required in less than 10% of the patients receiving intra-operative autotransfusion, this system was adopted as a more efficient method in routine TKA procedures.

Klíčová slova: post-operative retransfusion system, intra-operative autotransfusion system, total knee arthroplasty

Zveřejněno: 1. srpen 2012  Zobrazit citaci

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
KUČERA B, NÁHLÍK D, HART R, OCELÁKOVÁ L. Porovnání efektivnosti pooperačního retransfuzního systému s perioperačním autotransfuzním systémem při implantacích totálních endoprotéz kolenního kloubu. Acta Chir Orthop Traumatol Cech. 2012;79(4):361-366. doi: 10.55095/achot2012/052. PubMed PMID: 22980936.
Stáhnout citaci

Reference

  1. AZUMA, T., TAKAHASHI, S., KAWAMURA, A.: Preoperative autologous blood donation in hip surgeries. Transfus. Sci., 23: 177-181, 2000. Přejít k původnímu zdroji... Přejít na PubMed...
  2. BIERBAUM, B. E., CALLAGHAN, J. J., GALANTE, J. O., RUBASH, H. E., TOOMS, R. E., WELCH, B.: Ananalysis of blood management in patients having a total hip or knee arthroplasty. J. Bone Jt Surg., 81-A: 2-10, 1999. Přejít k původnímu zdroji... Přejít na PubMed...
  3. BLEVIS, F. T., SHAW, B., VALERI, R., KASSER, J., HALL, J.: Reinfusion of shed blood after orthopaedic procedures in children and adolescents. J. Bone Jt Surg., 75-A: 363-371, 1993. Přejít k původnímu zdroji... Přejít na PubMed...
  4. CHARROIS, O., KAHWAJI, A., VASTEL, L., ROSENBERG, N., COURPIED, J. P.: Blood loss in total hip arthroplasty for rapidly destructive coxarthrosis. Int. Orthop., 25: 22-24, 2001. Přejít k původnímu zdroji... Přejít na PubMed...
  5. CHENG, S. C., HUNG, T. S., TSE, P. Y.: Investigation of the use of drained blood reinfusion after total knee arthroplasty: a prospective randomised controlled study. J. Orthop. Surg. (Hong Kong), 13: 120-124, 2005. Přejít k původnímu zdroji... Přejít na PubMed...
  6. DRAMIS, A., PLEWES, J.: Autologous blood transfusion after primary unilateral total knee replacement surgery. Acta Orthop. Belg., 72: 15-17, 2006.
  7. DUCAN, J.: On re-infusion of blood in primary and other amputation. Br. Med. J., 30: 192-194, 1886. Přejít k původnímu zdroji... Přejít na PubMed...
  8. FARRIS, P. M., RITTER, M. A., KEATING, E. M., VALERI, R.: Unwashed filtered shed blood collected after knee and hip arthroplasties. J. Bone Jt Surg., 73-A: 1169-1178, 1991. Přejít k původnímu zdroji...
  9. GOODNOUGH, L. T., DESPOTIS, G. J., MERKEL, K., MONK, T. G.: A randomized trial Comparing acute normovolemic hemodilution and preoperative autologous blood donation in total hip arthroplasty. Transfusion, 40: 1054-1057, 2000. Přejít k původnímu zdroji... Přejít na PubMed...
  10. GRAMOLINI, R.: The Impact of the perioperative autotransfusion system OrthoPat(r)Haemonetics in orthopedic surgery. Transfusion alternatives in transfusion medicine, 4 (Suppl. 2): 27-29, 2002. Přejít k původnímu zdroji...
  11. GROSVENOR, D.,GOYAL, V., GOODMAN, S.: Efficacy of postoperative blood salvage following total hip arthroplasty in patients with and without deposited autologous units. J. Bone Jt Surg., 82-A: 951-954, 2000. Přejít k původnímu zdroji... Přejít na PubMed...
  12. HAN, C. D., SHIN, D. E.: Postoperative blood salvage and reinfusion after total joint arthroplasty. J. Arthroplasty, 12: 511-516, 1997. Přejít k původnímu zdroji... Přejít na PubMed...
  13. HANSEN, E.: Vorschlage zum internem Qualitatsmanagement bei der Retransfusion von intra und postoperativ gewonnenem Wund-Drainangeblut. Anasthesiol. Intensivmed., 43: 81-84, 2002.
  14. HEALLY, W. L., PFEIFFER, B. A., KURTZ, S. R., JOHNSON, C., JOHNSON, W., JOHNSTON, R., SANDERS, D., KARPMAN, R., HALLACKS, G. N., VALERI, R.: Evaluation of autologous shed blood for autotransfusion after orthopaedic surgery. Clin. Orthop., 299: 53-59, 1994. Přejít k původnímu zdroji...
  15. HELM, A. T., KARSKI, M. T., PARSONS, S. J., SAMPATH, J. S., BALE, R. S.: A strategy for reducing blood transfusion requirements in elective orthopaedic surgery. Audit of an algorithm for arthroplasty of the lower limb. J. Bone Jt Surg., 85-B: 484-489, 2003. Přejít k původnímu zdroji... Přejít na PubMed...
  16. HENDRYCH, J.: Použití setů pro pooperační drenáž a autotransfuzi u totálních náhrad kolenního kloubu. Acta Chir. orthop. Traum. čech., 73: 34-38, 2006. Přejít k původnímu zdroji...
  17. HIGHMORE, W.: Practical remarks on an overlooked source of blood-supply for transfusion in post-partum haemorrhage. Lancet, 89-92, 1874. Přejít k původnímu zdroji...
  18. JONES, H. W., SAVAGE, L.,WHITE, C.,GODDARD, R., LUMLEY, H., KASHIF, F., GURUSANY, K.: Postoperative autologous blood salvage drains - are they useful in primary uncemented hip and knee arthroplasty? A prospective study of 186 cases. Acta Orthop. Belg., 70: 466-473, 2004.
  19. LARSEN, R.: Anestezie. 351-355, 1. vydání, Praha, Grada Publishing s.r.o. 1998.
  20. LARSEN, R.: Anestezie. 747- 753, 7. přepracované a rozšířené vydání. Praha, Grada Publishing a.s. 2004.
  21. MUNOZ, M., ARIZA, D., GARCERAN, M. J., GOMEZ, A., CAMPOS, A.: Benefits of postoperative shed blood reinfusion in patients undergoing unilateral total knee replacement. Arch. Orthop. Trauma. Surg., 125: 385-389, 2005. Přejít k původnímu zdroji... Přejít na PubMed...
  22. MUNOZ, M., COBOS, A., CAMPOS, A., ARIZA, D., MUNOZ, E., GOMEZ, A.: Post-operative unwashed shed blood transfusion does not modify the cellular immune response to surgery for total knee replacement. Acta Anaesthesiol. Scand., 50: 443-450, 2006. Přejít k původnímu zdroji... Přejít na PubMed...
  23. REES, J. E., JEAVONS, R., DIXON, J. H.: An economic justification for autologous blood re-infusion in primary total knee replacement surgery. Ann. R. Coll. Surg. Engl., 87: 102-105, 2005. Přejít k původnímu zdroji... Přejít na PubMed...
  24. REIZE, P., ENDELE, D., RUDERT, M., WÜLKER, N.: Postoperative Rücktransfusion von Drainageblut in der Hüft-Endoprotetik - Wie gross ist der Nutzen wirklich? Z. Orthop., 144: 400-404, 2006. Přejít k původnímu zdroji... Přejít na PubMed...
  25. RIZZI, L., BERTACCHI, P., GHEZZI, L. M., BELLAVITA, P., SCUDELLER, G.: Postoperative blood salvage in hip and knee arthroplasty. A prospective study on cost effectiveness in 161 patients. Acta Orthop. Scand., 69: 31-34, 1998. Přejít k původnímu zdroji... Přejít na PubMed...
  26. ROSOLSKI, T., MAUERMANN, K.: Autologous Direct Re-Transfusion - Contra*. Transfus. Med. Hemother., 31: 232-235, 2004. Přejít k původnímu zdroji...
  27. SALIDO, J. A., MARIN, L. A., GOMEZ, L. A., ZORRILLA, P., MARTINEZ, C.: Preoperative emoglobin levels and the need for transfusion after prosthetic hip and knee surgery: analysis of predictive factors. J. Bone Jt Surg., 84-A: 216-220, 2002. Přejít k původnímu zdroji... Přejít na PubMed...
  28. TRČ, T., KVASNIČKA, J., KUDRNOVÁ, Z.: Prevence žilního tromboembolismu v ortopedii podle 7. konference American College of Chest Physicians (ACCP). Acta Chir. orthop. Traum. čech., 74: 126-131, 2007. Přejít k původnímu zdroji...
  29. WOJAN, M., SCHOLZ, R., VON SALIS-SOGLIO, G., SCHMIDT, M., WILD, A.: Retransfusion of unwashed drainage blood after total hip and knee arthroplasty. Biomed. Tech. (Berl.), 50: 355-360, 2005. Přejít k původnímu zdroji... Přejít na PubMed...
  30. WOOLSON, S. T., WATT, J. M.: Use of autologous blood in total hip replacement. A comparative program. J. Bone Jt Surg., 73-A: 76-80, 1991. Přejít k původnímu zdroji...
  31. XENAKIS, T. A., et al: Blood salvage after total hip and total knee arthroplasty. Acta Orthop. Scand., 68: 135-138, 1997. Přejít k původnímu zdroji... Přejít na PubMed...