Acta Chir Orthop Traumatol Cech. 2012; 79(5):404-410 | DOI: 10.55095/achot2012/057

Fixation of Osteoporotic Fractures in the Upper Limb with a Locking Compression PlateCurrent concepts review

NEUHAUS, V., KING, J. D., JUPITER, J. B.*
Hand and Upper Extremity Service, Massachusetts General Hospital, Orthopaedic Surgery, Boston, Massachusetts, USA

Locking Compression Plate (LCP) has the advantageous feature that screws can be locked in the plate leaving an angular stable construct. There is no need to have contact between the plate and the bone to achieve stability resulting from friction of the plate-bone-construct. Therefore the plate does not need to be contoured exactly to the bone and the healing bone's periosteal blood supply is not affected. The LCP is used as a bridging plate to gain relative stability in multi-fragmentary, diaphyseal or metaphyseal fractures. Depending on the fracture, the combination hole can also allow the LCP to achieve absolute stability similar to conventional fixation techniques.
Osteoporotic fractures have significant impact on morbidity and mortality. Proximal humeral and distal radius fractures are typical examples. These osteoporotic and often comminuted fractures are ideal settings/indications for LCP utilization in the upper extremity. However, the data quality is due to mostly small study populations not so powerful. Unquestionably there has been a clear and fashionable trend to choose operative treatment for these fractures, because the angular stability allows stable fixation and early functional mobilization.

Keywords: concepts, current, fractures, Locking Compression Plate, osteoporotic, review

Published: October 1, 2012  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
NEUHAUS V, KING JD, JUPITER JB. Fixation of Osteoporotic Fractures in the Upper Limb with a Locking Compression Plate. Acta Chir Orthop Traumatol Cech. 2012;79(5):404-410. doi: 10.55095/achot2012/057. PubMed PMID: 23140595.
Download citation

References

  1. ARORA, R., LUTZ, M., DEML, C., KRAPPINGER, D., HAUG, L., GABL, M.: A prospective randomized trial comparing nonoperative treatment with volar locking plate fixation for displaced and unstable distal radial fractures in patients sixty-five years of age and older. J. Bone Jt Surg., 93-A: 2146-2153, 2011. Go to original source... Go to PubMed...
  2. CALVO, E., MORCILLO, D., FORURIA, A. M., REDONDO-SANTAMARIA, E., OSORIO-PICORNE, F., CAEIRO, J. R.: Nondisplaced proximal humeral fractures: high incidence among outpatient-treated osteoporotic fractures and severe impact on upper extremity function and patient subjective health perception. J. Shoulder Elbow Surg., 20: 795-801, 2011. Go to original source... Go to PubMed...
  3. CAPO, J. T., KINCHELOW, T., BROOKS, K., TAN, V., MANIGRASSO, M., FRANCISCO, K.: Biomechanical stability of four fixation constructs for distal radius fractures. Hand (N Y), 4: 272-278, 2009. Go to original source... Go to PubMed...
  4. CHUDIK, S. C., WEINHOLD, P., DAHNERS, L. E.: Fixed-angle plate fixation in simulated fractures of the proximal humerus: a biomechanical study of a new device. J. Shoulder Elbow Surg., 12: 578-588, 2003. Go to original source... Go to PubMed...
  5. DIMITRIOU, R., JONES, E., McGONAGLE, D., GIANNOUDIS, P. V.: Bone regeneration: current concepts and future directions. BMC Med., 9: 66, 2011. Go to original source... Go to PubMed...
  6. DROBETZ, H., BRYANT, A. L., POKORNY, T., SPITALER, R., LEIXNERING, M., JUPITER, J. B.: Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction-a biomechanic study in a cadaveric model. J. Hand Surg. Am., 31: 615-622, 2006. Go to original source... Go to PubMed...
  7. DROBETZ, H., KUTSCHA-LISSBERG, E.: Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int. Orthop., 27: 1-6, 2003. Go to original source... Go to PubMed...
  8. EGOL, K. A., ONG, C. C., WALSH, M., JAZRAWI, L. M., TEJWANI, N. C., ZUCKERMAN, J. D.: Early complications in proximal humerus fractures (OTA Types 11) treated with locked plates. J. Orthop. Trauma, 22: 159-164, 2008. Go to original source... Go to PubMed...
  9. FJALESTAD, T., HOLE, M. O., HOVDEN, I. A., BLUCHER, J., STROMSOE, K.: Surgical treatment with an angular stable plate for complex displaced proximal humeral fractures in elderly patients: A randomized controlled trial. J. Orthop. Trauma, 26: 98-106, 2012. Go to original source... Go to PubMed...
  10. FOOTE, J. E., ROZENTAL, T. D.: Osteoporosis and upper extremity fragility fractures. J. Hand Surg. Am., 37: 165-167, 2012. Go to original source... Go to PubMed...
  11. GAEBLER, C., McQUEEN, M. M., COURT-BROWN, C. M.: Minimally displaced proximal humeral fractures: epidemiology and outcome in 507 cases. Acta Orthop. Scand., 74: 580-585, 2003. Go to original source... Go to PubMed...
  12. GAUTIER, E., SOMMER, C.: Guidelines for the clinical application of the LCP. Injury, 34 Suppl 2: B63-76, 2003. Go to original source... Go to PubMed...
  13. GIANNOUDIS, P., TZIOUPIS, C., ALMALKI, T., BUCKLEY, R.: Fracture healing in osteoporotic fractures: is it really different? A basic science perspective. Injury, 38 Suppl 1: S90-99, 2007. Go to original source... Go to PubMed...
  14. GREENDALE, G. A., BARRETT-CONNOR, E., INGLES, S., HAILE, R.: Late physical and functional effects of osteoporotic fracture in women: the Rancho Bernardo Study. J. Am. Geriatr. Soc., 43: 955-961, 1995. Go to original source... Go to PubMed...
  15. HANDOLL, H. H., GIBSON, J. N., MADHOK, R.: Interventions for treating proximal humeral fractures in adults. Cochrane Database Syst. Rev., CD000434, 2003. Go to original source...
  16. HARDEMAN, F., BOLLARS, P., DONNELLY, M., BELLEMANS, J., NIJS, S.: Predictive factors for functional outcome and failure in angular stable osteosynthesis of the proximal humerus. Injury, 43: 153-158, 2012. Go to original source... Go to PubMed...
  17. HERTEL, R.: Fractures of the proximal humerus in osteoporotic bone. Osteoporos Int., 16 Suppl 2: S65-572, 2005. Go to original source... Go to PubMed...
  18. HIRSCHMANN, M. T., FALLEGGER, B., AMSLER, F., REGAZZONI, P., GROSS, T.: Clinical longer-term results after internal fixation of proximal humerus fractures with a locking compression plate (PHILOS). J. Orthop. Trauma, 25: 286-293, 2011. Go to original source... Go to PubMed...
  19. ILYAS, A. M., JUPITER, J. B.: Distal radius fractures-classification of treatment and indications for surgery. Orthop. Clin. North Am., 38: 167-173, 2007. Go to original source... Go to PubMed...
  20. JUPITER, J. B.: The management of nonunion and malunion of the distal humerus a 30-year experience. J.Orthop. Trauma, 22: 742-750, 2008. Go to original source... Go to PubMed...
  21. JUPITER, J. B., MARENT-HUBER, M.: Operative management of distal radial fractures with 2.4 millimeter locking plates. A multicenter prospective case series. J. Bone Jt Surg., 91-A: 55-65, 2009. Go to original source... Go to PubMed...
  22. JUPITER, J. B., MARENT-HUBER, M.: Operative management of distal radial fractures with 2.4 millimeter locking plates: a multicenter prospective case series. Surgical technique. J. Bone Jt Surg., 92-A: Suppl 1 Pt 1: 96-106, 2010. Go to original source... Go to PubMed...
  23. JUPITER, J. B., WYSS, H.: Stable fixation of osteoporotic fractures and nonunions in the upper limb - life before the "locking plate". Acta Chir. orthop. Traum. čech., 77: 361-364, 2010. Go to original source...
  24. KANDEMIR, U., MATITYAHU, A., DESAI, R., PUTTLITZ, C.: Does a volar locking plate provide equivalent stability as a dorsal nonlocking plate in a dorsally comminuted distal radius fracture?: a biomechanical study. J. Orthop. Trauma, 22: 605-610, 2008. Go to original source... Go to PubMed...
  25. KANIS, J. A., JOHNELL, O., ODEN, A., SEMBO, I., REDLUND-JOHNELL, I., DAWSON, A., DE LAET, C., JONSSON, B.: Long-term risk of osteoporotic fracture in Malmo. Osteoporos Int., 11: 669-674, 2000. Go to original source... Go to PubMed...
  26. KELLER, M., STEIGER, R.: The pi plate: an implant for unstable extension fractures of the distal radius in patients with osteoporotic bone. Tech. Hand Up Extrem Surg., 8: 212-218, 2004. Go to original source... Go to PubMed...
  27. MATSCHKE, S., WENTZENSEN, A., RING, D., MARENT-HUBER, M., AUDIGE, L., JUPITER, J. B.: Comparison of angle stable plate fixation approaches for distal radius fractures. Injury, 42: 385-392, 2011. Go to original source... Go to PubMed...
  28. MUDGAL, C. S., JUPITER, J. B.: Plate fixation of osteoporotic fractures of the distal radius. J. Orthop. Trauma, 22: S106-115, 2008. Go to original source... Go to PubMed...
  29. NEER, C. S., 2nd: Displaced proximal humeral fractures. I. Classification and evaluation. J. Bone Jt Surg., 52-A: 1077-1089, 1970. Go to original source...
  30. OLERUD, P., AHRENGART, L., PONZER, S., SAVING, J., TIDERMARK, J.: Hemiarthroplasty versus nonoperative treatment of displaced 4-part proximal humeral fractures in elderly patients: a randomized controlled trial. J. Shoulder Elbow Surg., 20: 1025-1033, 2011. Go to original source... Go to PubMed...
  31. OYEN, J., BRUDVIK, C., GJESDAL, C. G., TELL, G. S., LIE, S. A., HOVE, L. M.: Osteoporosis as a risk factor for distal radial fractures: a case-control study. J. Bone Jt Surg., 93-A: 348-356, 2011. Go to original source... Go to PubMed...
  32. PALVANEN, M., KANNUS, P., PARKKARI, J., PITKAJARVI, T., PASANEN, M., VUORI, I., JARVINEN, M.: The injury mechanisms of osteoporotic upper extremity fractures among older adults: a controlled study of 287 consecutive patients and their 108 controls. Osteoporos Int., 11: 822-831, 2000. Go to original source... Go to PubMed...
  33. PARNES, N., JUPITER, J. B.: Fixed-angle locking plating of displaced proximal humerus fractures. Instr. Course Lect., 59: 539-552, 2010.
  34. RING, D.: Current concepts in plate and screw fixation of osteoporotic proximal humerus fractures. Injury, 38 Suppl 3: S59-68, 2007. Go to original source... Go to PubMed...
  35. RODERER, G., GEBHARD, F., KRISCHAK, G., WILKE, H. J., CLAES, L.: Biomechanical in vitro assessment of fixed angle plating using a new concept of locking for the treatment of osteoporotic proximal humerus fractures. Int. Orthop., 35: 535-541, 2011. Go to original source... Go to PubMed...
  36. ROZENTAL, T. D., BLAZAR, P. E.: Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J. Hand Surg. Am., 31: 359-365, 2006. Go to original source... Go to PubMed...
  37. RUCHELSMAN, D. E., MUDGAL, C. S., JUPITER, J. B.: The role of locking technology in the hand. Hand Clin., 26: 307-319; 2010. Go to original source... Go to PubMed...
  38. SCHILCHER, J., MICHAELSSON, K., ASPENBERG, P.: Bisphosphonate use and atypical fractures of the femoral shaft. N. Engl. J. Med., 364: 1728-1737, 2011. Go to original source... Go to PubMed...
  39. SHANE, E., BURR, D., EBELING, P. R., ABRAHAMSEN, B., ADLER, R. A., BROWN, T. D., CHEUNG, A. M., COSMAN, F., CURTIS, J. R., DELL, R., DEMPSTER, D., EINHORN, T. A., GENANT, H. K., GEUSENS, P., KLAUSHOFER, K., KOVAL, K., LANE, J. M., MCKIERNAN, F., MCKINNEY, R., NG, A., NIEVES, J., O'KEEFE, R., PAPAPOULOS, S., SEN, H. T., VAN DER MEULEN, M. C., WEINSTEIN, R. S., WHYTE, M.: Atypical subtrochanteric and diaphyseal femoral fractures: report of a task force of the American Society for Bone and Mineral Research. J. Bone Miner. Res., 25: 2267-2294, 2010. Go to original source... Go to PubMed...
  40. SIWACH, R., SINGH, R., ROHILLA, R. K., KADIAN, V. S., SANGWAN, S. S., DHANDA, M.: Internal fixation of proximal humeral fractures with locking proximal humeral plate (LPHP) in elderly patients with osteoporosis. J. Orthop. Traumatol., 9: 149-153, 2008. Go to original source... Go to PubMed...
  41. SOUER, J. S., RING, D., MATSCHKE, S., AUDIGE, L., MAREN-HUBERT, M., JUPITER, J.: Comparison of functional outcome after volar plate fixation with 2.4 mm titanium versus 3.5 mm stainless-steel plate for extra-articular fracture of distal radius. J. Hand Surg. Am., 35: 398-405, 2010. Go to original source... Go to PubMed...
  42. WAGNER, M.: General principles for the clinical use of the LCP. Injury, 34 Suppl 2: B31-42, 2003. Go to original source... Go to PubMed...
  43. YANG, H., LI, Z., ZHOU, F., WANG, D., ZHONG, B.: A prospective clinical study of proximal humerus fractures treated with a locking proximal humerus plate. J. Orthop. Trauma, 25: 11-17, 2011. Go to original source... Go to PubMed...
  44. ZIADE, N., JOUGLA, E., COSTE, J.: Population-level impact of osteoporotic fractures on mortality and trends over time: a nation wide analysis of vital statistics for France, 1968-2004. Am. J Epidemiol., 172: 942-951, 2010. Go to original source... Go to PubMed...
  45. ZYTO, K., AHRENGART, L., SPERBER, A., TORNKVIST, H.: Treatment of displaced proximal humeral fractures in elderly patients. J. Bone Jt Surg., 79-B: 412-417, 1997. Go to original source...