Acta Chir Orthop Traumatol Cech. 2013; 80(2):131-137 | DOI: 10.55095/achot2013/020

Orthogonal Double Plate Fixation for Long Bone Fracture NonunionOriginal papers

M. El Haj, A. Khoury, R. Mosheiff, M. Liebergall, Y. A. Weil*
Orthopaedic Surgery Depatment., Hadassah Hebrew University Medical Centre, Jerusalem, Israel

PURPOSE OF THE STUDY:
The treatment of long bone diaphyseal fracture-nonunion is challenging. While taking into account biological needs, a stable mechanical environment is pertinent for fracture healing. This work aims at evaluating the surgical management of stubborn ununited fractures using orthogonal double plating of diaphyseal fractures with limited periosteal stripping and soft tissue dissection.

PATIENTS AND METHODS:
Retrospective analysis in a level I trauma center. Between the years 2007-2009, 22 patients were treated with double plating due to nonunion of long bone fractures. Long bones included three clavicles, six humeri, three femora, seven ulnae, two tibiae and one radius. The mean period between index procedures (if existed) and revision procedures was 53.35 weeks (range 6 months-3 years). The same surgical technique, independent on the anatomical location was utilized. Perioperative intravenous antibiotics were withheld until intraoperative cultures were obtained in all patients. An approach to the fracture site was performed with removal of all previous existing hardware, including aggressive debridement of the nonunion site while keeping stripping to the necessary minimum. After primary plate fixation of the fracture with adequate compression, a second plate, with at least two well spaced screws on each side, was placed at a ninety degree angle to the primary plate. Autologous bone graft or bone graft substitute was placed in most, but not all cases. All procedures and assessment of union were done by fellowship trained trauma surgeons. In the infected cases, culture specific intravenous antibiotics were administered for six weeks. Quality of life measures included DASH score of the upper extremity, lower extremity functional score (LEFS) for the lower extremity and Short From 12 (SF-12) for all patients.

RESULTS:
Union was achieved in all patients, with an average time to union of 5.8 months (range 2-24 months). One patient healed after a repeat double plating, since the first procedure was unsuccessful. Tissue culture were positive in 11 out of 22 patients. One clavicular plate was removed, due to irritation. No hardware failure was noted in these cases. Mean LEFS was 59%, quick DASH score -18.5 20 and SF-12 MCS and PCS were 50.37 15.22 and 49.96 8.5 receptively.

CONCLUSION:
Double plating is a biomechanically sound option for treating long bone fracture nonunion with reasonable results, provided adequate biological conditions are met including eradication of infection.

Keywords: plate fixation, long bone nonunion, double plate technique

Published: April 1, 2013  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
El Haj M, Khoury A, Mosheiff R, Liebergall M, Weil YA. Orthogonal Double Plate Fixation for Long Bone Fracture Nonunion. Acta Chir Orthop Traumatol Cech. 2013;80(2):131-137. doi: 10.55095/achot2013/020. PubMed PMID: 23562257.
Download citation

References

  1. Amir, M., Lewin-Epstein, N., Becker, G., et al.: Psychometric properties of the SF-12 (Hebrew version) in a primary care population in Israel. Med. Care, 40: 918-928, 2002. Go to original source... Go to PubMed...
  2. Barbieri, C. H., Mazzer, N., Aranda, C. A., et al.: Use of a bone block graft from the iliac crest with rigid fixation to correct diaphyseal defects of the radius and ulna. J. Hand Surg., (Edinburgh, Scotland) 22: 395-401, 1997. Go to original source... Go to PubMed...
  3. Binkley, J. M., Stratford, P. W., Lott, S. A., et al.: The Lower Extremity Functional Scale (LEFS): scale development, measurement properties, and clinical application. North American Orthopaedic Rehabilitation Research Network. Phys. Ther., 79: 371-383, 1999. Go to original source...
  4. Dahabreh, Z., Dimitriou, R., Giannoudis, P. V.: Health economics: a cost analysis of treatment of persistent fracture non-unions using bone morphogenetic protein-7. Injury, 38: 371-377, 2007. Go to original source... Go to PubMed...
  5. Farouk, O., Krettek, C., Miclau, T., et al.: Effects of percutaneous and conventional plating techniques on the blood supply to the femur. Arch. Orthop. Trauma Surg., 117: 438-441, 1998. Go to original source... Go to PubMed...
  6. Farouk, O., Krettek, C., Miclau, T., et al.: Minimally invasive plate osteosynthesis: does percutaneous plating disrupt femoral blood supply less than the traditional technique? J. Orthop. Trauma, 13: 401-406, 1999. Go to original source... Go to PubMed...
  7. Friedrich, B., Klaue, P.: Mechanical stability and post-traumatic osteitis: an experimental evaluation of the relation between infection of bone and internal fixation. Injury, 9: 23-29, 1977. Go to original source... Go to PubMed...
  8. Helfet, D. L., Hotchkiss, R. N.: Internal fixation of the distal humerus: a biomechanical comparison of methods. J. Orthop. Trauma, 4: 260-264, 1990. Go to original source... Go to PubMed...
  9. Hübner, E. J., Hausschild, O., Südkamp, N. P., Strohm, P. C.: Clavicle fractures - is there a standard treatment? Acta Chir. orthop. Traum. čech., 78: 288-296, 2011. Go to original source...
  10. Chapman, M. W., Gordon, J. E., Zissimos, A. G.: Compression-plate fixation of acute fractures of the diaphyses of the radius and ulna. J. Bone Jt Surg., 71-A: 159-169, 1989. Go to original source...
  11. Jupiter, J. B., Wyss, H.: Stable fixation of osteoporotic fractures and nonunions in the upper limb - life before the "locking plate". Acta Chir. orthop. Traum. čech., 77: 361-364, 2010. Go to original source...
  12. Kabak, S., Halici, M., Tuncel, M., et al.: Treatment of midclavicular nonunion: comparison of dynamic compression plating and low-contact dynamic compression plating techniques. J. Shoulder Elbow Surg. / Am. Shoulder Elbow Surg., 13: 396-403, 2004. Go to original source... Go to PubMed...
  13. Knight, R. A., Purvis, G. D.: Fractures of both bones of the forearm in adults. J. Bone Jt Surg., 31-A: 755-764, 1949. Go to original source...
  14. Larson, A. N., Rizzo, M.: Locking plate technology and its applications in upper extremity fracture care. Hand Clin., 23: 269-78, vii., 2007. Go to original source... Go to PubMed...
  15. Lee, Y. S., Lin, C. C., Huang, C. R., et al.: Operative treatment of midclavicular fractures in 62 elderly patients: knowles pin versus plate. Orthopedics, 30: 959-964, 2007. Go to original source... Go to PubMed...
  16. O'Driscoll, S. W.: Optimizing stability in distal humeral fracture fixation. J. Shoulder Elbow Surg. / Am. Shoulder Elbow Surg., 14: 186S-194S, 2005. Go to original source... Go to PubMed...
  17. Prasarn, M. L., Ahn, J., Achor, T., et al.: Management of infected femoral nonunions with a single-staged protocol utilizing internal fixation. Injury, 40: 1220-1225, 2009. Go to original source... Go to PubMed...
  18. Prasarn, M. L., Ouellette, E. A., Miller, D. R.: Infected nonunions of diaphyseal fractures of the forearm. Arch. Orthop. Trauma Surg., 130: 867-873, 2010. Go to original source... Go to PubMed...
  19. Ring, D., Perey, B. H., Jupiter, J. B.: The functional outcome of operative treatment of ununited fractures of the humeral diaphysis in older patients. J. Bone Jt Surg., 81-A: 177-190, 1999. Go to original source... Go to PubMed...
  20. Rochet, S., Obert, L., Lepage, D., et al.: Proximal ulna comminuted fractures: Fixation using a double-plating technique. Orthop. Traumatol. Surg. Res., 96: 734-740, 2010. Go to original source... Go to PubMed...
  21. Rubel, I. F., Kloen, P., Campbell, D., et al.: Open reduction and internal fixation of humeral nonunions : a biomechanical and clinical study. J. Bone Jt Surg., 84-A: 1315-1322, 2002. Go to original source... Go to PubMed...
  22. Sanchez-Sotelo, J., Torchia, M. E., O'Driscoll, S. W.: Complex distal humeral fractures: internal fixation with a principle-based parallel-plate technique. J. Bone Jt Surg., 89-A: 961-969, 2007. Go to original source... Go to PubMed...
  23. Sanchez-Sotelo, J., Torchia, M. E., O'Driscoll, S. W.: Complex distal humeral fractures: internal fixation with a principle-based parallel-plate technique. Surgical technique. J. Bone Jt Surg., 90-A (Suppl 2 Pt 1): 31-46, 2008. Go to original source... Go to PubMed...
  24. Self, J., Viegas, S. F., Buford, W. L., Jr., et al.: A comparison of double-plate fixation methods for complex distal humerus fractures. J. Shoulder Elbow Surg. / Am. Shoulder Elbow Surg., 4: 10-16, 1995. Go to original source... Go to PubMed...
  25. Shen, J. W., Tong, P. J., Qu, H. B.: A three-dimensional reconstruction plate for displaced midshaft fractures of the clavicle. J. Bone Jt Surg., 90-B: 1495-1498, 2008. Go to original source... Go to PubMed...
  26. Spitzer, A. B., Davidovitch, R. I., Egol, K. A.: Use of a "hybrid" locking plate for complex metaphyseal fractures and nonunions about the humerus. Injury, 40: 240-244, 2009. Go to original source... Go to PubMed...
  27. Wagner, M.: General principles for the clinical use of the LCP. Injury, 34 (Suppl. 2): B31-42, 2003. Go to original source... Go to PubMed...
  28. Weber, B. G., Cech, O.: Pseudarthrosis. Grune and Stratton: New York; 1976, 104.
  29. Weresh, M. J., Hakanson, R., Stover, M. D., et al.: Failure of exchange reamed intramedullary nails for ununited femoral shaft fractures. J. Orthop. Trauma, 14: 335-338, 2000. Go to original source... Go to PubMed...
  30. Winquist, R. A., Hansen, S. T., Jr., Clawson, D. K.: Closed intramedullary nailing of femoral fractures. A report of five hundred and twenty cases. J. Bone Jt Surg., 66-A: 529-539, 1984. Go to original source...
  31. Worlock, P., Slack, R., Harvey, L., et al.: The prevention of infection in open fractures: an experimental study of the effect of fracture stability. Injury, 25: 31-38, 1994. Go to original source... Go to PubMed...
  32. Young, J. P., Stover, M. D., Magovern, B.: Treatment of isolated ulnar nonunions using wave plate osteosynthesis: a report of four cases. J. Orthop. Trauma, 23: 595-599, 2009. Go to original source... Go to PubMed...