Acta Chir Orthop Traumatol Cech. 2014; 81(2):140-151 | DOI: 10.55095/achot2014/016

Transpedikulárna stabilizácia zlomenín hrudnej chrbticePůvodní práce

M. BOŽÍK1,*, M. MAGALA2, T. HEGER2, D. MATEJIČKA2, J. BAKA2, P. ŠIMKO2
1 Oddelenie úrazovej chirurgie Fakultnej nemocnice s poliklinikou F. D. Roosevelta, Banská Bystrica
2 Klinika úrazovej chirurgie Univerzitnej nemocnice Bratislava a Lekárskej fakulty SZU

PURPOSE OF THE STUDY:
Fractures of the thoracic spine involve injury at the levels of Th2 to Th10. Because of pedicle morphology, pedicle screw fixation is a demanding procedure. However, evidence on the reliability and efficiency of this technique has recently been provided by several studies. The aim of this study was to analyse a group of patients with thoracic spine fractures treated by pedicle screw fixation and to evaluate treatment outcomes.

MATERIAL AND METHODS:
A total number of 33 patients treated by pedicle screw fixation for thoracic spine fractures between January 2007 and December 2011 were enrolled in this retrospective study. The mean age was 39.7±16.7 years. The evaluation included demographic data, mechanism of injury, associated injuries, neurological status, fracture type (AO classification), levels of the fractured vertebrae, injury-surgery interval, type and duration of surgery, type and length of pedicle screw fixation and complications. The position of pedicular screws in relation to the pedicle walls and correction of kyphotic deformity were assessed on post-operative CT scans.

RESULT:
Of the 33 patients, 24 had associated injuries (72.7%), 22 had thorax injury (66.7%) and 17 had neurological deficit (51.5%). The most frequent spinal fracture type was type B2, 15 (45.5%); followed by type C, nine (33.3%); and type B1, five (15.1%). The mean injury-to-surgery interval was 5.2±4.3 days. The mean operative time was 210±56 min. The most frequently used configuration of pedicle screw fixation involving two segments above and two below the fracture level was used in 20 cases (58.8%). The position of 149 out of 282 pedicle screws (52.8%) was evaluated on post-operative CT scans as follows: 98 % of the pedicle screws were placed in acceptable positions, 76% were placed completely within pedicle borders. The mean pre-operative Cobb angle was 18.7°±8.2°, the mean post-operative Cobb angle was 9.3±3.4°. Six intra-operative and three post-operative complications occurred. During follow-up no instrumentation failure or apparent loss of correction was recorded.

DISCUSSION:
Early stabilisation of thoracic spine fractures reduces the risk of complications, shortens the hospital stay and allows for faster recovery of patients. Early thoracic spine stabilisation is most beneficial in patients with a high ISS (Injury Severity Score). In the case of small-sized pedicles there is the possibility of pedicle screw insertion via an extrapedicular or parapedicular trajectory. Recommended pedicle screw fixation is two levels above and two levels below the fracture level.

CONCLUSIONS:
Pedicle screw fixation of thoracic spine fractures is a safe therapeutic method with a low risk of complications. It facilitates effective reduction and stable fixation with a low risk of secondary displacement and implant failure.

Klíčová slova: transpedicular stabilisation, thoracic spine, fracture, pedicle screws

Zveřejněno: 1. duben 2014  Zobrazit citaci

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
BOŽÍK M, MAGALA M, HEGER T, MATEJIČKA D, BAKA J, ŠIMKO P. Transpedikulárna stabilizácia zlomenín hrudnej chrbtice. Acta Chir Orthop Traumatol Cech. 2014;81(2):140-151. doi: 10.55095/achot2014/016. PubMed PMID: 25105789.
Stáhnout citaci

Reference

  1. ALOBAID, A., ARLET, V., OUELLET, J., REINDL, R.: Surgical technique - Technical notes on reduction of thoracic spine fracture dislocation : Can. J. Surg., 49: 131-134, 2006.
  2. ANDRIACCHI, T., SCHULTZ, A., BELyTSCHKO, T., GALANTE, J.: A model for studies of biomechanical interactions between human spine and rib cage. J. Biomech., 7: 497-507, 1974. Přejít k původnímu zdroji... Přejít na PubMed...
  3. BERG, E. E.: The sternal-rib complex : A possible fourth column in thoracic spine fractures. Spine, 18: 1916-1919, 1993. Přejít k původnímu zdroji...
  4. CARLSON, G. D., MINATO, y., OKADA, A. : Early time-dependent decompression for spinal cord injury: Vascular mechanisms of recovery. J. Neurotrauma, 14: 951-962, 1997. Přejít k původnímu zdroji... Přejít na PubMed...
  5. CARREON, L. Y., DIMAR, J. R.: Early versus late stabilisation of spine injuries : a systematic review. Spine, 36: E727-733, 2011. Přejít k původnímu zdroji... Přejít na PubMed...
  6. CINOTTI, G., GUMINA, S., RIPANI, M., POSTACCHINI, F.: Pedicle instrumentation in the thoracic spine. A morphometric and cadaveric study for placement of screws. Spine, 24: 114-119, 1999. Přejít k původnímu zdroji... Přejít na PubMed...
  7. CROCE, A., BEE, T. K., PRITCHARD, E., MILLER, P., FABIAN, T. C.: Does optimal timing for spine fracture fixation exist., Ann. Surg., 233: 851-858, 2001. Přejít k původnímu zdroji... Přejít na PubMed...
  8. DVORAK, M., MACDONALD, S., GURR, K. R., BAILEy, S. I., HADDAD, R. G.: An anatomic, radiographic, and biomechanical assessment of extrapedicular screw fixation in the thoracic spine. Spine, 18: 1689-1694, 1993. Přejít k původnímu zdroji... Přejít na PubMed...
  9. EBRAHEIM, N. A., JABALy, G., XU, R., yEASTING, R. A.: Anatomic relations of the thoracic pedicle to the adjacent neural structures. Spine, 22: 1553-1557, 1997. Přejít k původnímu zdroji... Přejít na PubMed...
  10. EBRAHEIM, N. A., XU, R., AHMAD, M., yEASTING, R. A.: Projection of the thoracic pedicle and its morphometric analysis. Spine, 22: 233-238, 1997. Přejít k původnímu zdroji... Přejít na PubMed...
  11. FEHLINGS, M., PERRIN, R. G. : The timing of surgical intervention in the management of spinal cord injury: A systematic review of recent clinical evidence. Spine, 31 (Suppl. 11): S28-S35, 2006. Přejít k původnímu zdroji... Přejít na PubMed...
  12. FISHER, C. G., SAHAJPAL, V., KEyNAN, O., BOyD, M., GRAEB, D., BAILEy, C.: Accuracy and safety of pedicle screw fixation in thoracic spine trauma. J. Neurosurg. Spine, 5: 520-526, 2006. Přejít k původnímu zdroji... Přejít na PubMed...
  13. FISHER, C., SINGH, S., BOyD, M., KINGWELL, S., KWON, B., LI, M., DVORAK, M.: Clinical and radiographic outcomes of pedicle screw fixation for upper thoracic spine (T1-T5) fractures: a retrospective cohort study of 27 cases. J. Neurosurg. Spine, 10: 207-213, 2009. Přejít k původnímu zdroji... Přejít na PubMed...
  14. FRANGEN, T. M., RUPPERT, S., MUHR, G., SCHINKEL, CH.: The beneficial effects of early stabilisation of thoracic spine fractures depend on trauma severity. J. Trauma, 68: 1208-1212, 2010. Přejít k původnímu zdroji... Přejít na PubMed...
  15. FURDERER, S., SCHOLTEN, N., COENEN, O., KOEBKE, J., EYSEL, P.: In-vitro comparison of the pullout strength of 3 different thoracic screw fixation techniques. J. Spinal Disord. Tech., 24: E6-10, 2011. Přejít k původnímu zdroji... Přejít na PubMed...
  16. GERTZBEIN, S. D., ROBBINS, R. E.: Accuracy of pedicular screw placement in vivo. Spine, 15: 11-14, 1990. Přejít k původnímu zdroji... Přejít na PubMed...
  17. HANLEY, E. N., Jr., ESKAY, M. L.: Thoracic spine fractures. Orthopedics, 12: 689-696, 1989 Přejít k původnímu zdroji... Přejít na PubMed...
  18. HUSTED, D. S., HAIMS, A. H., FAIRCHILD, T. A., KERSHAW, T. S., YUE, J. J. : Morphometric comparison of the pedicle rib unit to pedicles in the thoracic spine. Spine, 29: 139-146, 2004. Přejít k původnímu zdroji... Přejít na PubMed...
  19. HUSTED, D. S., YUE, J. J., FAIRCHILD, T. A., HAIMS, A. H. : An extrapedicular approach to the placement of screws in the thoracic spine: an anatomic and radiographic assessment. Spine, 28: 2324-2330, 2003. Přejít k původnímu zdroji... Přejít na PubMed...
  20. KIM, y. J., LENKE, L. G., BRIDWELL, K. H., CHO, y. S., RIEW, K. D.: Free hand pedicle screw placement in the thoracic spine: is it safe? Spine, 29: 333-342, 2004. Přejít k původnímu zdroji... Přejít na PubMed...
  21. KOTHE, R., O'HOLLERAN, J. D., LIU, W., PANJABI, M. M.: Internal architecture of the thoracic pedicle. An anatomic study. Spine, 21: 264-270, 1996. Přejít k původnímu zdroji... Přejít na PubMed...
  22. KRBEC, M., ŠTULÍK, J.: Osteosyntéza zlomenin Th/L páteře vnitřním fixatérem. Zhodnocení 120 operovaných případů. Acta Chir. orthop. Traum. čech., 68: 77-84, 2001.
  23. LUKÁŠ, R., BARSA, P., PAZOUR, J., ŠRÁM, J. : Timing operací páteře při akutním poškození míchy a jeho vliv na vývoj neurologického nálezu, Acta Chir. orthop. Traum. čech., 79: 233-237, 2012. Přejít k původnímu zdroji...
  24. MAGERL, F., AEBI, M., GERTZBEIN, S. D., HARMS, J., NAZARIAN, S.: A comprehensive classification of thoracic and lumbar injuries. Eur. Spine J., 3: 184-201, 1994. Přejít k původnímu zdroji... Přejít na PubMed...
  25. MARRÉ, B., BALLESTEROS, V., MARTINEZ, C., ZAMORANO, J. J., ILABACA, F., MUNJIN, M., YURAC, R., URZUA, A., LECAROS, M., FLEIDERMAN, J.: Thoracic spine fractures: injury profile and outcomes of a surgically treated cohort. Eur. Spine J., 20: 1427-1433, 2011. Přejít k původnímu zdroji... Přejít na PubMed...
  26. MATĚJKA, J., SKÁLA-ROSENBAUM, J., KRBEC, M., ZEMAN, J., MATĚJKA, T., ZEMAN, P.: Poranění hrudní a bederní páteře typu B3 dle AO-ASIF. Acta Chir. orthop. Traum. čech., 80: 235-240, 2013. Přejít k původnímu zdroji...
  27. PANJABI, M. M., O'HOLLERAN, J. D., CRISCO, J. J. III, KOTHE, R.: Complexity of the thoracic spine pedicle anatomy. Eur. Spine J., 6: 19-24, 1997. Přejít k původnímu zdroji... Přejít na PubMed...
  28. PAPADOPOULOS, S. M., SELDEN, N. R., QUINT, D. J. : Immediate spinal cord decompression for cervical spinal cord injury : Feasibility and outcome. J. Trauma, 52: 323-332, 2002. Přejít k původnímu zdroji... Přejít na PubMed...
  29. SINGH, R., TAyLOR, D., DSOUZA, D., GORELI, A., PAGE, P., PHAL, P.: Injuries significantly associated with thoracic spine fractures : a case control study. Emerg. Med. Australas, 21: 419-423, 2009. Přejít k původnímu zdroji... Přejít na PubMed...
  30. SOREFF, J., AXDORPH, G., ByLUND, P., ODEEN, I., OLERUD, S.: Treatment of patients with unstable fractures of the thoracic and lumbar spine: a follow-up study of surgical and conservative treatment. Acta Orthop. Scand., 53: 369-381, 1982. Přejít k původnímu zdroji... Přejít na PubMed...
  31. STOVAL, D. O., GOODRICH, A., MACDONALD, A., BLOM,, P.: Pedicle screw instrumentation for unstable thoraco-lumbar fractures. J. South Orthop. Assoc., 5: 165-173, 1996.
  32. VACCARO, A. R., RIZZOLO, S. J., ALLARDYCE, T. J., RAMSEY, M., SALVO, J., BALDERSTON, R. A.: Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the thoracic vertebrae. J. Bone Jt Surg., 77-A: 1193-1199, 1995. Přejít k původnímu zdroji... Přejít na PubMed...
  33. VACCARO, A. R., DAUGHERTy, R. J., SHEENAN, T. P.: Neurologic outcome of early versus late surgery for cervical spinal cord injury. Spine, 22: 2609-2613, 1997. Přejít k původnímu zdroji... Přejít na PubMed...
  34. VIALLE, L. R., VIALLE, E. : Thoracic spine fractures. Injury, 36: S-B65-S-B72, 2005. Přejít k původnímu zdroji...
  35. WHITE, K. K., OKA, R., MAHAR, A. T., LOWRy, A., GARFIN, S. R. : Pullout strength of thoracic pedicle screw instrumentation: comparison of the transpedicular and extrapedicular technique. Spine, 31: E355-358, 2006. Přejít k původnímu zdroji... Přejít na PubMed...
  36. XIE, J., WANG, y., ZHAO, Z., ZHANG, y.: The safe placement of upper and middle thoracic pedicle screws in pediatric deformity. J. Spinal Disord. Tech., 24: 55-59, 2011. Přejít k původnímu zdroji... Přejít na PubMed...
  37. yUE, J. J., SOSSAN, A., SELGRATH, C., DEUTSCH, L., WILKENS, K., TESTAIUTI, M.: The treatment of unstable thoracic spine fractures with transpedicular screw instrumentation: a 3-year consecutive series. Spine, 27: 2782-2787, 2002.