Acta Chir Orthop Traumatol Cech. 2015; 82(2):145-151 | DOI: 10.55095/achot2015/021
Zkušenosti s cementovaným anatomicky tvarovaným dříkem SAS I - střednědobé výsledkyPůvodní práce
- Ortopedické oddělení, Nemocnice Třebíč, příspěvková organizace, Třebíč
PURPOSE OF THE STUDY:
In view of increasing interest in a relationship between the surface of an implant and its behaviour and longevity in total hip arthroplasty (THA), the aim of this study is to present the clinical and radiographic results, as well as complications, of hip replacement surgery using the cemented femoral stem SAS I.
MATERIAL AND METHODS:
A total of 298 cemented femoral stems SAS I were implanted in 275 patients at our department between 1996 and 2005. The patient average age was 72.1 years, with the range from 64 to 92 years. The pre-operative diagnoses were as follows: primary osteoarthritis in 179 (30.1%); post-dysplastic osteoarthritis in 41 (13.7%); femoral neck fracture in 44 (14.8%); avascular necrosis of the femoral head in 23 (7.7%); rheumatoid arthritis in nine (3%) and other causes in two (0.7%) patients. Of the 275 patients who had the surgery, 186 (204 THAs) underwent clinical and X-ray examination at an average follow-up of 11.5 years (range, 8 to 17 years). The clinical results were used to calculate the Harris hip score and radiographic evaluation was based on antero-posterior views.
RESULTS:
The group of 186 assessed patients (204 THAs) comprised 106 women and 80 men, who were on average 85.4 years old on evaluation (range, 72 to 92 years). Of the remaining patients, 62 patients (64 THAs) died from causes unrelated to the surgery and 27 patients (30 THAs) were lost to follow-up. The functional outcome of surgery assessed by the Harris hip score was excellent in 61 (32.8%), good in 94 (50.5%), satisfactory in 26 (14%) and poor in five (2.7%) patients. The 93.1% SAS I stem longevity was recorded in relation to aseptic loosening; reimplantation for this indication was performed in 14 THAs. No revision surgery for failure due to valgus/varus deviations of the stem was carried out. Of the 204 hips, 188 had femoral stems aligned in neutral, 12 (5.9%) in valgus and four (2%) in varus positions.
DISCUSSION:
The anatomical femoral stem SAS I is an implant made to fit the proximal femur anatomy. Its highly polished surface allows for optimal fitting with the supporting bone and for even distribution of weight bearing. This results in a low rate of THA failure. In accordance with the relevant literature, the acetabular components is considered to be the weakest element in total hip replacement in terms of aseptic loosening and implant failure. At present, the SAS I stem has no Morse Eurocone taper and this is the chief obstacle hindering its more frequent use in endoprosthetics.
CONCLUSIONS:
The results of our study are in agreement with those of other successfully implanted polished cemented femoral components.
Klíčová slova: anatomical cemented femoral component, surface adjustment of the femoral stem, complications
Zveřejněno: 1. duben 2015 Zobrazit citaci
ACS | AIP | APA | ASA | Harvard | Chicago | Chicago Notes | IEEE | ISO690 | MLA | NLM | Turabian | Vancouver |
Reference
- ALEJANDRO, G. D. V., COMBA, F.: Favouable midterm result of the VerSys CT polished cemented femoral stem for total hip arthroplasty. Int. Orthop., 30: 381-386, 2006.
Přejít k původnímu zdroji...
Přejít na PubMed...
- BAUMANN, B., BARTHEL, T., HEDRICH, CH.: 9- to 11-year results of cemented titanium Mueller straight stem in total hip arthroplasty. Orthopedics, 20: 551-557, 2007.
Přejít k původnímu zdroji...
Přejít na PubMed...
- CORTEN, K., MCCALDEN, R. W., TEO, Y.: Midterm results of 506 solid trispiked reflection cementless acetabular components for primary total hip arthroplasty. J. Arthroplasty, 11: 1350-1356, 2011.
Přejít k původnímu zdroji...
Přejít na PubMed...
- CYPRICH, J., FOUSEK, J.: První zkušenosti s implantací cementovné endoprotézy kyčelního kloubu Saphir I. Acta Chir. orthop. Traum. čech., 64: 99-103, 1997.
- ČECH, O., PAVLANSKY, R.: Aloplastika kyčelního kloubu. Praha, Avicenum 1983.
- DANIEL, C. J. K., GARDENIERS, J., VETH, R.: Good results with cemented total hip arthroplasty in patients between 40 and 50 years age. Acta Orthop., 81: 165-170, 2010.
Přejít k původnímu zdroji...
Přejít na PubMed...
- DONG, H. S., HO, H. Y., SUNG, K. CH., WON, Y. S.: Fifteen-year results of precoated femoral stem in primary hybrid total hip arthroplasty. Clin. Orthop. Surg., 5: 110-117, 2013.
Přejít k původnímu zdroji...
Přejít na PubMed...
- DUNCAN, C. P., MASRI, B. A.: Review fractures of the femur after hip replacement. Instr. Course Lect., 44: 293-304, 1995.
- GACON, G.: A propos des tiges femorales cimentees en alliage de titane. Maitrise Orthopedique, 8: 23-27, 1998.
- GALLO, J., MRÁZEK, F., PETŘEK, M.: Podíl imunogenetických faktorů na vzniku a rozvoji periprotetické osteolýzy. Acta Chir. orthop. Traum. čech., 74: 247-252, 2007.
Přejít k původnímu zdroji...
- GULAN, G., JURDANA, H. SESTAN, B., LEGOVIC, D., RATKO, S.: Analysis of aseptically loosened cemented femoral stems in three types of hip prosthesis. Fifth SICOT/SIROT Annual International Conference, Marrakech 2007 - Abstract book, SIC01-P26, 2007.
- HAMADOUCHE, M., BAQUE, F., LEFEVRE, N.: Minimum 10-year survival of Kerboull cemented stems according to surface finish. Clin. Orthop. Relat. Res., 466: 332-339, 2008.
Přejít k původnímu zdroji...
Přejít na PubMed...
- JEWETT, B. A., COLLIS, D. K.: Radiographic failure patterns of polished cemented stems. Clin. Orthop. Relat. Res., 453: 132-136, 2006.
Přejít k původnímu zdroji...
Přejít na PubMed...
- KOVAC, S., TREBSE, R., MILOSEV, I.: Long term survival of cemented titanium aluminium vanadium alloy straight stem femoral component. J. Bone Jt Surg., 88-B: 1567-1573, 2006.
Přejít k původnímu zdroji...
Přejít na PubMed...
- LANGLAIS, F.: Tolérance des prothéses totales de hanche en alliage de titane. Ann. Orthop. Ouest., 25: 61-66, 1996.
- LANGLAIS, F., KERBOUL, M., SEDEL,L., LING R. S.: The "French paradox". J. Bone Jt Surg., 85: 17-20, 2003.
Přejít k původnímu zdroji...
Přejít na PubMed...
- LAPPALAINEN, R., SANTAVIRTA, S. S.: Potential of coatings in total hip replacement. Clin. Orthop. Relat. Res., 430: 72-79, 2005.
Přejít k původnímu zdroji...
Přejít na PubMed...
- LENA, T., DŽUPA, V., LUŇÁČEK, L., FRIC, V., KRBEC, M.: Peroperační periprotetické zlomeniny u TEP kyčelního kloubu v letech 1995-2009. Acta Chir. orthop. Traum. čech., 80: 341-345, 2013.
Přejít k původnímu zdroji...
- MANLEY, M. T., STERN, L. S., GURTOWSKI, J.: The load carrying and fatigue properties of the stem cemented interface with smooth and porous coated femoral componenets. J. Biomed Res. 19: 563-575, 1985.
Přejít k původnímu zdroji...
Přejít na PubMed...
- MORSCHER, E. W., BERLI, B., CLAUSS, M., GRAPPIOILO, G.: Outcomes of the MS-30 cemented femoral stem. Acta Chir. orthop. Traum. čech., 72: 153-159, 2005.
- OSOROVITZ, P., GOUTALLIER, D.: Résultats cliniques et radiographiques d une serie cotinue de 124 prothéses totales de hanche type OSTEAL avec courbes de survie á 9 ans. Rev. Chir. Orthop., 80: 305-315, 1994.
- PASSUTI, N., BERTRAND, O., GOUIN, F., POTAUX, J. V., BAIBVEL, N.: Etude actuarielle á 10 ans d une serie de prothéses totales de hanche OSTEAL. Rev. Chir. Orthop., 82 (Suppl. I): 135, 1996.
- PATRICK, B., LAZENNEC, J.-Y., POUPON, J., ROUSSEAU, M.-A., RAVAUD, P., CATONNÉ, Y.: Clinical and biological assessment of cemented titanium femoral stems: an 11-year experience. Int. Orthop., 33: 1209-1215, 2009.
Přejít k původnímu zdroji...
Přejít na PubMed...
- PECOUT, C., ARNAUD, J. P.: Systeme anatomique saphir I SAS, Centre Hospital Universitaire Hopital Dupuytren. Limoges 1994.
- RAMANIRAKA, N. A., RAKOTOMANANA, L. R., LEYVRAZ, P.F.: The fixation of the cemented femoral component. Effects of stem stiffness, cement thickness and roughness of the cement-bone surface. J. Bone Jt Surg., 82-B: 297-303, 2000.
Přejít k původnímu zdroji...
- ROZKYDAL, Z., JANÍČEK, P.: Cemetovaný dřík TEP Poldi-Čech po 25 letech. Acta Chir. otrhop. Traum. čech., 77: 284-290, 2010.
Přejít k původnímu zdroji...
- SEDEL, L., NIZARD, R. S., KERBOULL L., WITVOET, J.: Alumina-alumina hip replacement in patients younger than 50 years old. Clin. Orthop., 298: 175-183, 1994.
Přejít k původnímu zdroji...
- SCOTT, G., FREEMAN, M., KERBOULL, M.: Femoral components. The French Paradox. In: Breusch, S.J., Malchau, H.: The well-cemented total hip arthroplasty. Heidelberg, Springer Medizin Verlag 2005, 249-253.
Přejít k původnímu zdroji...
- SUH, D. H., YUN, H. H., CHUN, S. K.: Fifteen year results of precoated femoral stem in primary hybrid total hip arthroplasty. Clin. Orthop. Surg., 5: 110-117, 2013.
Přejít k původnímu zdroji...
Přejít na PubMed...
- VERDONSCHOT, N., HUISKES, R.: Mechanical effects of stem cement interface characteristics in total hip replacement. Clin. Orthop., 329: 326-336, 1996.
Přejít k původnímu zdroji...
Přejít na PubMed...
- WEISSINGER, M., HELMREICH, C., PÖLL, G.: Periprotetické zlomeniny v oblasti kyčelního kloubu. Acta. Chir. orthop. Traum. čech., 76: 179-185, 2009.
Přejít k původnímu zdroji...
- WILLERT, H. G.: Crevice corrsion of cemented titanium alloy stems in total hip replacements. Clin. Orthop., 333: 51-75, 1996.
Přejít k původnímu zdroji...
- WITT, J. D., SWANN, M.: Metal wear and tissue response in failed titanium alloy total hip replacement. J. Bone Jt Surg., 73-B: 559-563, 1991
Přejít k původnímu zdroji...
Přejít na PubMed...