Acta Chir Orthop Traumatol Cech. 2008; 75(3):212-220 | DOI: 10.55095/achot2008/040

Use of Angle-Stable Implants for Proximal Humeral Fractures: Prospective StudyOriginal papers

M. KŘIVOHLÁVEK*, R. LUKÁŠ, S. TALLER, J. ŠRÁM
Traumacentrum Krajské nemocnice Liberec

PURPOSE OF THE STUDY:
To evaluate and compare proximal humeral fractures treated either by plate osteosynthesis with angular-stable screws or by intramedullary nailing, and to define the indications optimal for use of either technique.

MATERIAL:
The study comprised 97 patients. The proximal humeral internal locking system (PHILOS) plate was used in 49 patients (31 women and 18 men); with age average 57.4 years (women, 64.5 and men, 45.3 years). By the AO classification, 12 patients with type A, 15 with type B, and 22 with type C fractures. The Targon PH nail was used in 48 patients (32 women and 16 men) at an average age of 65.3 years (women, 72.2 and men, 51.4 years). Type A fractures were in 18, type B in 18 and type C in 12 patients.

METHODS:
The patients were prospectively evaluated and placed into the two groups. The post-operative range of motion was assessed by tthe Constant-Murley (CM) score at 6 weeks, and at 3, 6 and 12 months. The CM value was related to the healthy collateral limb and recorded as a relative CM score.

RESULTS:
In the PHILOS group, the average values were: operative time, 76.2 min; X-ray exposure, 4.2 min; and relative CM score, 74.5 points. The Targon PH group showed the average operative time of 50.2 min., X-ray exposure for 4 min. and the relative CM score 78.3 points. There were no signifficant differences between the groups, with the exception of shorter operative time in intramedullary nailing.

DISCUSSION:
Nailing is the method of choice for two-fragment fractrues. In comminutive metaphyseal fractures particularly, the use of nailing is more effective than plate osteosynthesis that carries the risk of plate detachment from the diaphysis. In fractures with a long fracture line extending into the metaphysis, plate osteosynthesis with open reduction is a better option.
The results in three-fragment fractures are comparable and the choice of an implant is the matter of surgeon's preference. The standard technique for four-fragment fractures involves the use of angular-stable plate fixation through the deltoid-pectoral approach. Intramedullary nailing is a borderline indication requiring a modified surgical procedure, with tubercles being fixed with osteosuture.

CONCLUSIONS:
No statistically significant differences in functional results occurred between the observed groups at one year of follow-up. In four-fragment proximal humerus fractures, the patients treated with Targon PH nails had more complications and worse relative CM scores than those treated with PHILOS plates; however, this was not statistically significant and the number of complications decreased after the technique of tubercle osteosuture had been introduced. Finally, the only significant difference between the groups was a shorter operative time with the use of intramedullary nailing.

Keywords: proximal humeral fractrues, angular-stable implants, plate osteosynthesis, intramedullary nailing, prospective study

Accepted: January 8, 2008; Published: June 1, 2008  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
KŘIVOHLÁVEK M, LUKÁŠ R, TALLER S, ŠRÁM J. Use of Angle-Stable Implants for Proximal Humeral Fractures: Prospective Study. Acta Chir Orthop Traumatol Cech. 2008;75(3):212-220. doi: 10.55095/achot2008/040. PubMed PMID: 18601820.
Download citation

References

  1. ADEDAPO, A.O., IKPEME, J.O.: The results of internal fixation of three- and four-part proximal humeral fractures with the Polarus nail. Injury, 32: 115-121, 2001. Go to original source... Go to PubMed...
  2. BARTONÍČEK, J., STEHLÍK, J., DLOUHÝ, M.: Osteosyntéza zlomenin proximálního konce humeru modifikovanou dlahou. Acta Chir. orthop. Traum. čech., 62: 207-220, 1995.
  3. BERNARD J., CARALAMBIDES C., ADERINTO J., MOK D.: Early failure of intramedullary nailing for proximal humeral fractures. Injury, 31: 789-792, 2000. Go to original source... Go to PubMed...
  4. BLUM, J., HESSMANN, M., H., ROOMMENS, P., M: Treatment of proximal metaphyseal fractures of the humerus with interlocked nailing and a spiral blade - early experience with a new implant system. Act. Traumatol., 33: 7-13, 2003.
  5. CONSTANT, C. R., MURLEY A. H.: A clinical method of functional assessment of the shoulder. Clin. Orthop., 216: 91-110, 1987. Go to original source...
  6. CUNY, C., IRAZZI, M., NEYTON, L., BERRICHI, A., BEAU, P.: Telegraph nail used for internal fixation of proximal humerus fracture. Europ. J. Orthop. Surg. Taumat., 10: 21-26, 2000. Go to original source...
  7. EISELE, R., KINZL, L.: Nailing of Articular and Extraarticular Fractures of the Head of the Humerus. Osteo Trauma Care, 10: S1-4, 2002. Go to original source...
  8. FRIČ V.: Operační řešení tříštivých zlomenin proximálního konce humeru: Optimalizace terapeutické koncepce. Praha, Závěrečná zpráva IGA MZ ČR, 2000.
  9. GARDNER M. et al.: The extended anterolateral acromial approach allows minimally invasive access to the proximal humerus. Clin. Orthop., 434: 123-129, 2005. Go to original source... Go to PubMed...
  10. HENTE, R., KAMPSHOFF, J., KINNER, B., FUCHTMEIER, B., NERLICH, M.: Treatment of displaced 3- and 4-part fractures of the proximal humerus with fixator plate comprising angular stability. Unfallchirurg, 107: 769-782, 2004. Go to original source... Go to PubMed...
  11. HERTEL, R., Fractures of the proximal humerus in osteoporotic bone. Osteoporosis In, 16: S65-S72, 2005. Go to original source... Go to PubMed...
  12. HESSEMAN, M., STERNSTEIN, W., BLUM, J., KRUMMENAUER, F., ROMMENS, P., M.: Osteosyntesis of proximal humeral Fractures with angular-stable plate fixation. Act. Traumatol., 33: 2-6, 2003. Go to original source...
  13. HOFFMEYER, P.: The operative management of displaced fractures of the proximal humerus. J. Bone Jt Surg., 84-B: 469-480, 2002. Go to original source...
  14. KINZL, L., EISELE, R, LIENER, U.: The treatment of proximal humerus fractures with intramedullary nails. Act. Traumatol., 35: 108-112, 2005. Go to original source...
  15. KŘIVOHLÁVEK, M., LUKÁŠ, R., TALLER, S., ŠRÁM, J.: Použití úhlově stabilní dlahy Philos u zlomenin proximálního humeru. Úraz. Chir., 13: 52-59, 2005.
  16. LILL, H., HEPP, P., HOFFMANN, J., LABOROWITZ, J., KORNER, J., JOSTEN, CH, DUDA, J: Neue implantate zur stabilisierung proximaler humerusfrakturen. Osteosyntese International, 9: 85-93, 2001. Go to original source...
  17. LILL, H., HEPP, P., ROSE, Z., KONIG, K., JOSTEN, C.: The angle stable locking-proximal-humerus-plate (LPHP) for proximal humeral fractures using a small anterior-lateral-deltoid-splitting-approach - technique and first results. Zbl. Chir., 129: 43-48, 2004.
  18. LIN, J., HOU, SM., HANG YS.: Locked nailing for displaced surgical neck fractures of the humerus. J. Trauma, 45: 1051-1057, 1998. Go to original source... Go to PubMed...
  19. LINHART, W., GROSSTERLINDEN, L., HASSUNIZADEH, B., JANSSEN, A., SOMMERRFELDT, D, W., RUEGER, M, J.: A New Approach to Operative treatment of Proximal Humeral Fractures: Intramedullary Nailing with Fixed-Angle Locking Screws. Osteo Trauma Care, 10: S83-85, 2002. Go to original source...
  20. LINN, J. : Effectiveness of Locked Nailing for Displaced Three - Part Proximal Humeral Fractures. J. Trauma, 61: 363-374. 2005. Go to original source... Go to PubMed...
  21. MATHEWS, J., LOBENHOFFER, P.: Results of Intramedullary nailing of Unstable Proximal Humeral Fractures in Geriatric Patients with a New Nail System. Unfallchirurg, 107: 372-380, 2004.
  22. MITLMEIER, W. F., STEDFELD, H. W., EWERET, A., BECK, M., FROSCH, B., GRADL G.: Stabilisation of Proximal Humeral Fractures with an Angular and Sliding Stable Antegrade Locking Nail (Targon PH). J. Bone Jt Surg., 85: 136-146, 2003. Go to original source... Go to PubMed...
  23. NEER, C., S.: Four-segment classification of proximal humeral fractures: Purpose and reliable use. J. Shoulder Elbow Surg., 11: 389-400, 2002. Go to original source... Go to PubMed...
  24. PLECKO, M., KRAUS, A.: Internal fixation of proximal humerus fractures using the locking proximal humerus plate. Operat. Orthop. Traumatol., 17, 25-50, 2005. Go to original source... Go to PubMed...
  25. RING, D.: Current concepts in plate and screw fixation of osteoporotic proximal humerus fractures. Injury, 38S3, 59-68, 2007. Go to original source... Go to PubMed...
  26. ROOYEN, R., S. et al.: Humeral head collapse causing locked screw penetration of the glenohumeral joint. An implant specific complication of the proximal humeral locking plate (PHILOS). Injury extra, 37: 462-465, 2006. Go to original source...
  27. SCHWARTZ, C., CUNY, C.: Fractures of the proximal humerus: a prospective review of 188 cases, Europ. J. Orthop. Surg. Traumatol., 13: 1-12, 2003. Go to original source...
  28. SOSNA, A., POKORNÝ, D., VAVŘÍK, P., JAHODA, D.: Endoprotéza ramenního kloubu v traumatických indikacích - operační technika. Acta Chir. Orthop. Traum. čech., 71: 265-271, 2004.
  29. STEDFELD, H., WICK, M., WINKLER, R., ATTMANSPACHER, W.: Nail fixation osteosyntesis: indications, technique, practical progress. Proximal humerus. Trauma Berufskranknh. 6: Suppl 2, S241-246, 2004. Go to original source...
  30. ŠRÁM, J., LUKÁŠ, R., KŘIVOHLÁVEK, M., TALLER, S.: Použití hřebu Targon PH long u etážových zlomenin a zlomenin metafýzy proximálního humeru. Rozhl. Chir., 86: 254-262, 2007.
  31. TALLER, S., KŘIVOHLÁVEK, M., LUKÁŠ, R., KRÁL, M: Hemiartroplastika v léčbě zlomenin proximálního humeru. Acta Chir. orthop., Traum. čech., 74: 262-267, 2007. Go to original source...
  32. VIŠŇA, P., BEITL, E., JAGANJAC, E., KALVACH, J., ŠMÍDL, Z: Ošetření zlomenin proximálního humeru pomocí úhlově stabilního antegrádního zajištěného nitrodřeňového hřebu - prospektivní studie. Rozhl. Chir., 86, 194-200, 2007.
  33. ZYTO K.: Non-operative treatment of comminuted fractures of the proximal humerus in elderly patients. Injury, 29: 349-352, 1998. Go to original source... Go to PubMed...