Acta Chir Orthop Traumatol Cech. 2009; 76(1):60-64 | DOI: 10.55095/achot2009/010
Custom-Designed 3D Tibial Augmentation for Knee ReplacementCase report
- 1 Stomatologická klinika 1. LF UK a VFN, Praha
- 2 I. ortopedická klinika 1. LF UK a FN Motol, Praha
- 3 Laboratoř biomechaniky, Fakulta strojní, ČVUT, Praha
Reconstruction with the use of custom-made implants aims at optimal replacement of lost or damaged bone structures and restoration of their funkction. In this study the development and construction of a custom-made implant and the operative technique used for the treatment of an extensive tibial defect are described.
The patient was a 65-year-old man treated for over 20 years for psoriatic arthritis and severe instability of the right knee, particularly in the frontal plane, with a worsening varus deformity. The radiogram showed an extensive destruction of the medial tibial condyle that also deeply involved the lateral condyle. The extent of defect made it impossible to use any commercial tibial augmentation. The geometry of the custom-designed implant for the medial tibial condyle was constructed on the basis of a 3D defect model and the shape of the medial tibial condyle of the collateral knee seen on CT scans. After its correct shape was verified on a plastic model, its coordinates were set in the software of a machine tool, and a titanium augmentation otherwise compatible with a standard knee replacement was produced. The use of such a custom implant to complete standard total knee arthroplasty has so far been demanding in terms of organisation and manufacture. Its production in the future could be facilitated by substituting titanium for plastic material such as poly-ether-ether-ketone (PEEK).
Keywords: custom-made implant, tibial augmentation, knee prosthesis
Accepted: July 15, 2008; Published: February 1, 2009 Show citation
References
- DELÉPINE, F., JUND, S., SCHLATTERER, B., DE PERETTI, F.: Experience with Poly Ether Ether Ketone (PEEK) cages and locking plate for anterior cervical fusion in the treatment of spine trauma without cord injury. Rev. Chir. orthop., 93: 789-97, 2007.
Go to original source...
Go to PubMed...
- HARRYSSON, O. L. A., HOSNI, Y. A., NAYFEH, J. F.: Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case study. BMC Musculoskeletal Disorders, 8: 1-10, 2007.
Go to original source...
Go to PubMed...
- JIANKANG, H., DICHEN, L., BINGHENG, L., ZHEN, W., TAO, Z.: Custom fabrication of composite tibial hemi-knee joint combining CAD/CAE/CAM techniques. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 220: 823-830, 2006.
Go to original source...
Go to PubMed...
- KULKARNI, A., HEE, H., WONG, H.: Solis cage (PEEK) for anterior cervical fusion: preliminary radiological results with emphasis on fusion and subsidence. The Spine Journal, 7: 205-209, 2007.
Go to original source...
Go to PubMed...
- LEE, M. Y., CHANG, CH. CH., LIN, CH. CH., LO, L. J., CHEN, Y. R.: Custom implant design for patients with cranial defects. Engineering in Medicine and Biology Magazine, 21: 38-44, 2002.
Go to original source...
Go to PubMed...
- MASON, J. B., SCOTT, R. D.: Management of severe bone loss. Prosthetic modularity and custom implants. In: Lotke, P. A., Garino, P. J. (Eds): Revison Total Knee Arthroplasty. Philadelphia, Lippincott-Raven 1998, 207-216.
- NETVAL, M., HUDEC, T., HACH, J.: Naše zkušenosti s endoprotetikou kolenního kloubu po tuberkulózní artritidě (1980-2005). Acta Chir. orthop. Traum. čech., 74: 111-113, 2007.
- PASCALE, V., PASCALE, W.: Custom-made Articulating Spacer in Two-stage Revision Total Knee Arthroplasty. An Early Follow-up of 14 Cases of at Least 1 Year After Surgery. Hospital for the Special Surgery Journal, 3: 159-163, 2007.
Go to original source...
Go to PubMed...
- ROZKYDAL, Z., JANÍK, P., JANÍČEK, P., KUNOVSKÝ, R.: Revizní náhrada kolena po aseptickém uvolnění. Acta Chir. orthop. Traum. čech., 74: 5-13, 2007
Go to original source...
- STARLY, B., FANG, Z., SUN, W., SHOKOUFANDEH, A., REGLI, W.: Three-Dimensional Reconstruction for Medical-CAD Modeling. Computer-Aided Design & Applications, 2: 431-438, 2005.
Go to original source...
- STÁREK, M., STEHLÍK, J., HELD, M.: Zkušenosti s totální náhradou kolenního kloubu typu Beznoska S. V. L. Acta Chir. orthop. Traum. čech., 71: 352-359, 2004.
- VAVŘÍK, P., SOSNA, A., JAHODA, D., POKORNÝ, D.: Endoprotéza kolenního kloubu. Praha, Triton 2005.